Real-time neural inverse optimal control for a wind generator
R Ruiz-Cruz, EN Sanchez… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
This paper presents a discrete-time inverse optimal control scheme using a neural network
for a doubly fed induction generator (DFIG). The DFIG generation scheme has a …
for a doubly fed induction generator (DFIG). The DFIG generation scheme has a …
MPPT control methods in wind energy conversion system using DFIG
A Kadri, H Marzougui, F Bacha - 2016 4th International …, 2016 - ieeexplore.ieee.org
This paper presents a review of two Maximum Power Point Tracking (MPPT) methods used
in order to extracting maximum possible power from the wind energy conversion systems …
in order to extracting maximum possible power from the wind energy conversion systems …
[图书][B] Doubly fed induction generators: control for wind energy
EN Sanchez, R Ruiz-Cruz - 2016 - taylorfrancis.com
Doubly Fed Induction Generators: Control for Wind Energy provides a detailed source of
information on the modeling and design of controllers for the doubly fed induction generator …
information on the modeling and design of controllers for the doubly fed induction generator …
Harmonic compensation for variable speed DFIG wind turbines using multiple reference frame theory
J Li, K Corzine - 2015 IEEE Applied Power Electronics …, 2015 - ieeexplore.ieee.org
This paper proposes novel methods to compensate the grid current harmonics by controlling
the back to back converter of dual-fed induction generator (DFIG). The selected low-order …
the back to back converter of dual-fed induction generator (DFIG). The selected low-order …
Congestion management in modern power system containing active distribution network nodes
X Wang, C Jiang - Electric Power Components and Systems, 2016 - Taylor & Francis
This article presents a novel methodology to determine a transmission congestion
management strategy for a power system containing active distribution network nodes …
management strategy for a power system containing active distribution network nodes …
A sensorless flux oriented control scheme for a DFIG connected to a DC link
J Li, K Corzine - 2015 Clemson University Power Systems …, 2015 - ieeexplore.ieee.org
In this paper, a novel sensorless flux-oriented control scheme is presented to connect a
DFIG to a dc link with arbitrary stator frequency. The rotor side of the DFIG is connected to …
DFIG to a dc link with arbitrary stator frequency. The rotor side of the DFIG is connected to …
Comparative evaluation of different power quality issues of variable speed wind turbines
I Ahmed - 2017 - bura.brunel.ac.uk
The generation of wind energy deliberately becomes a significant part of generated
electrical power in developed nations. Factors like fluctuation in natural wind speed and the …
electrical power in developed nations. Factors like fluctuation in natural wind speed and the …
[PDF][PDF] Validating Response of AC Microgrid to Line-to-Line Short Circuit in Islanded Mode Using Dynamic Analysis
MA Aminu - academia.edu
This paper is presented in an attempt to validate the dynamic response of a microgrid to line-
to-line short circuit. The microgrid components include two identical Wind Turbine …
to-line short circuit. The microgrid components include two identical Wind Turbine …
[PDF][PDF] A Robust control of Doubly-fed Induction Generator Using in Wind Energy Conversion System
This paper presents a study analysis of a wind energy conversion system (WECS) based on
a doubly fed induction generator (DFIG) connected to the electric power grid. The aim of this …
a doubly fed induction generator (DFIG) connected to the electric power grid. The aim of this …