Review of international grid codes for wind power integration: Diversity, technology and a case for global standard

M Mohseni, SM Islam - Renewable and Sustainable Energy Reviews, 2012 - Elsevier
This paper presents a comprehensive study on the latest grid code regulations enforced by
transmission system operators on large wind power plants (WPPs). First, the most common …

Doubly-fed induction generator based wind turbines: A comprehensive review of fault ride-through strategies

JJ Justo, F Mwasilu, JW Jung - Renewable and sustainable energy reviews, 2015 - Elsevier
This paper presents an over-review of various strategies applied to enhance the fault ride-
through (FRT) capability of the doubly-fed induction generators (DFIGs) based wind turbines …

An improved low-voltage ride-through control strategy of doubly fed induction generator during grid faults

S Hu, X Lin, Y Kang, X Zou - IEEE transactions on power …, 2011 - ieeexplore.ieee.org
This paper presents a control strategy to improve the low-voltage ride-through capability of a
doubly fed induction generator (DFIG); since the stator of a DFIG is directly connected to a …

A combined vector and direct power control for DFIG-based wind turbines

J Mohammadi, S Vaez-Zadeh… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
In this paper, a combined vector and direct power control (CVDPC) is proposed for the rotor
side converter (RSC) of doubly fed induction generators (DFIGs). The control system is …

Impacts of symmetrical and asymmetrical voltage sags on DFIG-based wind turbines considering phase-angle jump, voltage recovery, and sag parameters

M Mohseni, SM Islam… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
This paper presents a new analysis into the impacts of various symmetrical and
asymmetrical voltage sags on doubly fed induction generator (DFIG)-based wind turbines …

Direct power control of doubly fed induction generator under distorted grid voltage

H Nian, Y Song - IEEE Transactions on Power Electronics, 2013 - ieeexplore.ieee.org
This paper presents a direct power control (DPC) strategy for a doubly fed induction
generator (DFIG)-based wind power generation system under distorted grid voltage. By …

Review on FRT solutions for improving transient stability in DFIG‐WTs

A Rini Ann Jerin, P Kaliannan… - IET Renewable …, 2018 - Wiley Online Library
Fault‐ride‐through (FRT) is an imperative capability in wind turbines (WTs) to ensure grid
security and transient stability. However, doubly fed induction generator‐based WTs (DFIG …

Advanced multi-sector P&O maximum power point tracking technique for wind energy conversion system

AR Youssef, AIM Ali, MSR Saeed… - International Journal of …, 2019 - Elsevier
This article suggests a new solution for the limitations of conventional fixed step-size perturb
and observe (PO) maximum power point tracking (MPPT) of the wind energy conversion …

[PDF][PDF] Design and implementation of high performance field oriented control for grid-connected doubly fed induction generator via hysteresis rotor current controller

F Amrane, A Chaiba, BE Babes… - Rev. Roum. Sci. Techn …, 2016 - revue.elth.pub.ro
DESIGN AND IMPLEMENTATION OF HIGH PERFORMANCE FIELD ORIENTED CONTROL
FOR GRID-CONNECTED DOUBLY FED INDUCTION GENERATOR VIA HYSTE Page 1 Rev …

A hysteresis current controller for single-phase three-level voltage source inverters

H Mao, X Yang, Z Chen, Z Wang - IEEE Transactions on Power …, 2012 - ieeexplore.ieee.org
Conventional hysteresis current controllers have the disadvantage of a variable switching
frequency. This paper presents a novel hysteresis current control method which uses the …