Dark-field computed tomography reaches the human scale

M Viermetz, N Gustschin, C Schmid… - Proceedings of the …, 2022 - National Acad Sciences
X-ray computed tomography (CT) is one of the most commonly used three-dimensional
medical imaging modalities today. It has been refined over several decades, with the most …

Technical design considerations of a human-scale Talbot-Lau interferometer for dark-field CT

M Viermetz, N Gustschin, C Schmid… - … on Medical Imaging, 2022 - ieeexplore.ieee.org
Computed tomography (CT) as an important clinical diagnostics method can profit from
extension with dark-field imaging, as it is currently restricted to X-rays' attenuation contrast …

A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions

S Gkoumas, P Villanueva-Perez, Z Wang, L Romano… - Scientific reports, 2016 - nature.com
In X-ray grating interferometry, dark-field contrast arises due to partial extinction of the
detected interference fringes. This is also called visibility reduction and is attributed to small …

Non-destructive testing of archaeological findings by grating-based X-ray phase-contrast and dark-field imaging

V Ludwig, M Seifert, T Niepold, G Pelzer, J Rieger… - Journal of …, 2018 - mdpi.com
The analysis of archaeological findings reveals the remaining secrets of human history.
However, it is a challenging task to investigate and simultaneously preserve the unique …

A beam hardening and dispersion correction for x‐ray dark‐field radiography

G Pelzer, G Anton, F Horn, J Rieger, A Ritter… - Medical …, 2016 - Wiley Online Library
Purpose: X‐ray dark‐field imaging promises information on the small angle scattering
properties even of large samples. However, the dark‐field image is correlated with the …

Quantitative analysis of speckle-based X-ray dark-field imaging using numerical wave-optics simulations

S Meyer, SZ Shi, N Shapira, ADA Maidment… - Scientific Reports, 2021 - nature.com
The dark-field signal measures the small-angle scattering strength and provides
complementary diagnostic information. This is of particular interest for lung imaging due to …

Exploration of different x-ray Talbot–Lau setups for dark-field lung imaging examined in a porcine lung

V Ludwig, M Seifert, C Hauke, K Hellbach… - Physics in Medicine …, 2019 - iopscience.iop.org
X-ray dark-field imaging is a promising technique for lung diagnosis. Due to the alveolar
structure of lung tissue, a higher contrast is obtained by the dark-field image compared to the …

Virtual grating approach for Monte Carlo simulations of edge illumination-based x-ray phase contrast imaging

J Sanctorum, J Sijbers, J De Beenhouwer - Optics Express, 2022 - opg.optica.org
The design of new x-ray phase contrast imaging setups often relies on Monte Carlo
simulations for prospective parameter studies. Monte Carlo simulations are known to be …

Designing the phase grating for Talbot-Lau phase-contrast imaging systems: a simulation and experiment study

J Rieger, P Meyer, G Pelzer, T Weber, T Michel… - Optics …, 2016 - opg.optica.org
The performance of a Talbot-Lau interferometer depends to a great extent on its visibility.
This means, to obtain high quality phase-contrast and dark-field images a high visibility is …

Modeling of an X-ray grating-based imaging interferometer using ray tracing

JP Wilde, L Hesselink - Optics Express, 2020 - opg.optica.org
X-ray imaging by means of a grating-based Talbot-Lau interferometer has become an
important tool for a wide variety of application areas such as security, medical and materials …