Precision of ISO 3382-2 and ISO 3382-3–A Round-Robin test in an open-plan office

V Hongisto, J Keränen, L Labia, R Alakoivu - Applied Acoustics, 2021 - Elsevier
International standards ISO 3382-2 and ISO 3382-3 are increasingly applied to determine
the room acoustic conditions in open-plan offices because attention to noise control in such …

Time–frequency methods for characterization of room impulse responses and decay time measurement

L Čurović, J Murovec, T Novaković, J Prezelj - Measurement, 2022 - Elsevier
In the low frequency range, the reverberation of a room should be characterized by the
decay time, which can be determined experimentally by various methods. In order to make …

Experimental evaluations of acoustic properties and long-term analysis of a novel indoor living wall

F Scamoni, C Scrosati, M Depalma, B Barozzi - Journal of Building …, 2022 - Elsevier
Indoor living walls are important decorative elements that can recreate a natural garden in
enclosed spaces. Several aspects are addressed by the scientific literature such as, for …

Assessment of the airborne sound insulation from mobility vibration measurements; a hybrid experimental numerical approach

NB Roozen, Q Leclere, D Urbán… - Journal of Sound and …, 2018 - Elsevier
A new measurement procedure is proposed to assess the airborne sound insulation of a
partition under diffuse sound field excitation using mobility measurements combined with a …

On the use of dynamic vibration absorbers to counteract the loss of sound insulation due to mass-spring-mass resonance effects in external thermal insulation …

NB Roozen, D Urbán, EA Piana, C Glorieux - Applied Acoustics, 2021 - Elsevier
One of the common ways to increase the energy performance of existing buildings is to add
a thermal insulation layer to their façade elements, which in turn is covered by a thin …

Uncertainty of facade sound insulation by a Round Robin Test. Evaluations of low-frequency procedure and single numbers

C Scrosati, F Scamoni, A Prato, S Secchi, P Fausti… - Building and …, 2016 - Elsevier
The international standard ISO 140-5 for the measurement of the sound insulation of
building facades has been recently replaced by the new standard ISO 16283-3. The revised …

Revision of international standards on field measurements of airborne, impact and facade sound insulation to form the ISO 16283 series

C Hopkins - Building and Environment, 2015 - Elsevier
This paper gives the background to the main technical changes concerning the field
measurement of sound insulation in the new ISO 16283 series of standards for airborne …

Experimental evaluation of the sound absorption and insulation of an innovative coating through different testing methods

F Scamoni, EA Piana, C Scrosati - Building Acoustics, 2017 - journals.sagepub.com
The Lombardy Region and the Construction Technologies Institute of the National Research
Council of Italy are promoting the development of an innovative coating nano-material for …

Uncertainty of façade sound insulation in buildings by a round robin test

C Scrosati, F Scamoni, G Zambon - Applied Acoustics, 2015 - Elsevier
The uncertainty of field measurements of a façade was evaluated by a Round Robin Test
(RRT) conducted in a full-scale experimental building at the Construction Technologies …

Influence of low frequency bands on airborne and impact sound insulation single numbers for typical Portuguese buildings

J António, D Mateus - Applied Acoustics, 2015 - Elsevier
This paper presents an analysis of in situ measurements for airborne and impact sound
insulation performed in typical buildings in Portugal. The direct partition element separating …