Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Non-structural elements and the dynamic response of buildings: A review
A Devin, PJ Fanning - Engineering Structures, 2019 - Elsevier
The primary structural system of a building is designed to resist a variety of loads. In addition
to this primary system, there are secondary systems or so-called 'non-structural'elements …
to this primary system, there are secondary systems or so-called 'non-structural'elements …
Experimental behaviour of high strength steel end-plate connections
AMG Coelho, FSK Bijlaard - Journal of Constructional Steel Research, 2007 - Elsevier
The use of high strength steel in construction has recently provided some challenges to
structural engineers. One such challenge is to minimise the cross-section dimensions as the …
structural engineers. One such challenge is to minimise the cross-section dimensions as the …
Behaviour of stainless steel beam-to-column joints—Part 1: Experimental investigation
Research on stainless steel structures has primarily focused on the structural response of
individual members, whilst the response of joints has received far less attention to date. This …
individual members, whilst the response of joints has received far less attention to date. This …
Post-Northridge connections with slit dampers to enhance strength and ductility
H Saffari, AA Hedayat, MP Nejad - Journal of Constructional Steel …, 2013 - Elsevier
In 1994 and 1995, Northridge and Kobe earthquakes caused unexpected damages to beam-
to-column connections which were followed by extensive investigations on the connections' …
to-column connections which were followed by extensive investigations on the connections' …
[HTML][HTML] Exploring innovative techniques for damage control during natural disasters
The study critically examines the principles, mechanisms, and effectiveness of different
damage control techniques in dealing with natural disasters, emphasizing their pivotal role …
damage control techniques in dealing with natural disasters, emphasizing their pivotal role …
Mechanical behavior of a replaceable energy dissipation device for precast concrete beam-column connections
G Hu, W Huang, H **e - Journal of Constructional Steel Research, 2020 - Elsevier
A replaceable energy dissipation device for precast concrete beam-column connections is
proposed in this paper, which is comprised by a short length of a H-shaped steel section …
proposed in this paper, which is comprised by a short length of a H-shaped steel section …
Numerical and analytical study of stainless steel beam-to-column extended end-plate connections
MM Eladly, BW Schafer - Engineering Structures, 2021 - Elsevier
Based on a shell finite element modeling protocol developed and verified by the first author
in a previous study, a comprehensive investigation on stainless steel extended end-plate …
in a previous study, a comprehensive investigation on stainless steel extended end-plate …
Study of stainless steel bolted extended end-plate joints under seismic loading
Y Bu, Y Wang, Y Zhao - Thin-Walled Structures, 2019 - Elsevier
Bolted stiffened extended end-plate (BSEP) joint is a commonly used beam-to-column joint
in steel frames. In this paper, five full-scale stainless steel BSEP joints were tested under …
in steel frames. In this paper, five full-scale stainless steel BSEP joints were tested under …
Experimental evaluation of rigid connection with reduced section and replaceable fuse
ARM Garoosi, M TahamouliRoudsari, BH Hashemi - Structures, 2018 - Elsevier
Abstract The reduced Beam Section (RBS) connection was proposed after the 1994
Northridge earthquake. By creating a plastic hinge outside the connection area, this …
Northridge earthquake. By creating a plastic hinge outside the connection area, this …
Double reduced beam section connection
In this paper, a novel beam-to-column steel moment connection, named “double reduced
beam section (DRBS)” is introduced and the seismic performance of the connection is …
beam section (DRBS)” is introduced and the seismic performance of the connection is …