[HTML][HTML] Optimized TOF-PET detector using scintillation crystal array for brain imaging
H Leem, Y Choi, J Jung, K Park, Y Kim… - Nuclear Engineering and …, 2022 - Elsevier
Research groups in the field of PET instrumentation are studying time-of-flight (TOF)
technology to improve the signal-to-noise ratio of PET images. Scintillation light transport …
technology to improve the signal-to-noise ratio of PET images. Scintillation light transport …
Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elements
Excellent timing resolution is required to enhance the signal-to-noise ratio (SNR) gain
available from the incorporation of time-of-flight (ToF) information in image reconstruction for …
available from the incorporation of time-of-flight (ToF) information in image reconstruction for …
Reflectivity quenching of ESR multilayer polymer film reflector in optically bonded scintillator arrays
The 3M-ESR multilayer polymer film is a widely used reflector in scintillation detector arrays.
As specified in the datasheet and confirmed experimentally by measurements in air, it is …
As specified in the datasheet and confirmed experimentally by measurements in air, it is …
Impact of geometry on light collection efficiency of scintillation detectors for cryogenic rare event searches
Simulations of photon propagation in scintillation detectors were performed with the aim to
find the optimal scintillator geometry, surface treatment, and shape of external reflector in …
find the optimal scintillator geometry, surface treatment, and shape of external reflector in …
Effect of tungsten do** on ZnMoO4 scintillating bolometer performance
The introduction of a small quantity of tungsten oxide (in the range 0.2–0.5 wt%) into the melt
improves the growth of ZnMoO 4 crystals. No significant difference in the kinetics of …
improves the growth of ZnMoO 4 crystals. No significant difference in the kinetics of …
Study of light transport inside scintillation crystals for PET detectors
X Yang, E Downie, T Farrell… - Physics in Medicine & …, 2013 - iopscience.iop.org
Scintillation crystal design is a critical component in positron emission tomography system
development, which impacts a number of performance parameters including energy …
development, which impacts a number of performance parameters including energy …
Refractive index measurement of cerium-doped LuxY2− xSiO5 single crystal
Principal refractive indices of the biaxial cerium-doped LuxY2− xSiO5 (LYSO) crystal were
determined with high accuracy at seven different wavelengths between 400 and 700nm …
determined with high accuracy at seven different wavelengths between 400 and 700nm …
Optimization of light collection from crystal scintillators for cryogenic experiments
High light collection efficiency is an important requirement in any application of scintillation
detectors. The purpose of this study is to investigate the possibility for improving this …
detectors. The purpose of this study is to investigate the possibility for improving this …
Simulation of scintillation light output in LYSO scintillators through a full factorial design
F Loignon-Houle, M Bergeron, CM Pepin… - Physics in Medicine …, 2017 - iopscience.iop.org
Individually coupled scintillation detectors used in positron emission tomography (PET)
imaging suffer from important signal losses due to the suboptimal light collection from …
imaging suffer from important signal losses due to the suboptimal light collection from …
Development of highly integrated PET/MR detector modules
I Sacco - 2016 - archiv.ub.uni-heidelberg.de
In the last 20 years, PET imaging has become a very valuable technique for clinical
diagnosis. It gives functional information on glucose metabolism and cancerous cell growth …
diagnosis. It gives functional information on glucose metabolism and cancerous cell growth …