Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Surface coating effect on corrosion resistance of titanium alloy bone implants by anodizing method
In the presented work, the formation of anodic oxide film on Ti-6Al-4V ELI (Extra Low
Interstitial) alloy in 0.02 M trisodium phosphate (Na 3 PO 4) electrolyte solution using various …
Interstitial) alloy in 0.02 M trisodium phosphate (Na 3 PO 4) electrolyte solution using various …
[HTML][HTML] Design of a transforaminal lumbar interbody fusion (TLIF) spine cage
Lumbar Interbody Fusion is a technique used to treat various spinal disorders, which has
many types, such as the Transforaminal Lumbar Interbody Fusion (TLIF) Technique. With …
many types, such as the Transforaminal Lumbar Interbody Fusion (TLIF) Technique. With …
[HTML][HTML] Evaluation of the contact area in total knee arthroplasty designed for deep knee flexion
Total knee arthroplasty (TKA) implants are becoming an interesting subject in implant design
research and development activities due to their complexity. They should be able to facilitate …
research and development activities due to their complexity. They should be able to facilitate …
Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model
Total hip replacement (THR) with cemented stem is a common procedure for patients with
hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses …
hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses …
[HTML][HTML] Fabrication of rigid polyurethane foam lumbar spine model for surgical training using indirect additive manufacturing
Fabrication of Rigid Polyurethane Foam Lumbar Spine Model for Surgical Training using
Indirect Additive Manufacturing title Title Author Issue Keywords Current Issue : Vol 16, No 1 …
Indirect Additive Manufacturing title Title Author Issue Keywords Current Issue : Vol 16, No 1 …
Evaluation varus stress in total knee arthroplasty designed for deep knee flexion using knee kinematic motion simulator
J Triwardono, H Purnama, W Sulistyo… - AIP Conference …, 2024 - pubs.aip.org
Revision total knee arthroplasties cause performed aseptic loosening, instability, and
polyethylene wear. The collaboration between surgeons and engineers for resulted in many …
polyethylene wear. The collaboration between surgeons and engineers for resulted in many …
Evaluation of the Malalignment Varus-Valgus in Total Knee Arthroplasty Designed for Deep Knee Flexion Using Knee Kinematic Motion Simulator
J Triwardono, F Rokhmanto, R Roberto… - Journal of …, 2023 - Trans Tech Publ
Revision total knee arthroplasties cause performed aseptic loosening, instability, and
polyethylene wear. Separation or removal of the femoral component has been observed and …
polyethylene wear. Separation or removal of the femoral component has been observed and …
[HTML][HTML] Development of Patient-Specific Adaptive Assistive Devices for Brachial Plexus Injury
Injury to the brachial plexus prevents the arm, wrist, and hand from communicating with the
spinal cord in whole or in part. The'patient's upper arm limb appears to be completely …
spinal cord in whole or in part. The'patient's upper arm limb appears to be completely …
[HTML][HTML] Modelling Human-Structure Interaction in Sideways Fall for Hip Impact Force Estimation
Sideways fall-induced hip fracture is a primary global health concern among the elderly.
Existing impact models for predicting peak hip impact force mostly consider the human body …
Existing impact models for predicting peak hip impact force mostly consider the human body …
Fracture Analysis of Resurfaced Femur with Varus Implant Placement
Clinical reports have mentioned the cases of femoral bone fracture after resurfacing hip
arthroplasty which happened to the patients with varus implant placement. This study has …
arthroplasty which happened to the patients with varus implant placement. This study has …