Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Anisotropic magnetic properties of antiferromagnetic
B Song, Z Shan, R Shi, S Yang, R Li, J Min, Z Ma… - Physical Review B, 2024 - APS
We report a detailed study of the physical properties of single crystals of DyCoGa 5 using
magnetic susceptibility, specific heat, and resistivity measurements. DyCoGa 5 crystallizes in …
magnetic susceptibility, specific heat, and resistivity measurements. DyCoGa 5 crystallizes in …
Multiple metamagnetic transitions in the helical antiferromagnet
We report on neutron diffraction, magnetoresistance, magnetization and magnetic torque
measurements under high magnetic field in the helical antiferromagnet CeVGe 3. This …
measurements under high magnetic field in the helical antiferromagnet CeVGe 3. This …
Anomalous quantum oscillations of in high magnetic fields
J Hornung, S Mishra, J Stirnat, M Raba, BV Schwarze… - Physical Review B, 2021 - APS
We report on magnetic-torque and resistivity measurements of the heavy-fermion compound
CeCoIn 5 in static magnetic fields up to 36 T and temperatures down to 50 mK. While …
CeCoIn 5 in static magnetic fields up to 36 T and temperatures down to 50 mK. While …
An Integrated Dual-Mode Pulse-Echo Ultrasonic Measurement System Under Pulsed/Static Magnetic Field
W Qiu, J Zhang, Y Luo, X Han - IEEE Transactions on Industrial …, 2023 - ieeexplore.ieee.org
Ultrasonic measurements at high magnetic fields and low temperatures necessitate ultrafast
excitations, ultrahigh dynamic range of duty-cycle adjustments, and real-time, precise, and …
excitations, ultrahigh dynamic range of duty-cycle adjustments, and real-time, precise, and …
[PDF][PDF] Novel ordered phases and quantum criticality of 4f-electron systems in high magnetic fields and ultra-low temperatures
FG Bangma - 2023 - repository.ubn.ru.nl
In this thesis, we have studied the properties of the two 4f-electron systems PrOs4Sb12 and
Cd-doped CeIrIn5 in high magnetic fields and in ultra-low and low temperatures …
Cd-doped CeIrIn5 in high magnetic fields and in ultra-low and low temperatures …
Application of FPGA based Lock-in amplifier for ultrasound propagation measurements using the pulse-echo technique
We describe application of a state-of-the art digital FPGA based Lock-In amplifier to
measurements of ultrasound propagation and attenuation at fixed frequency in low …
measurements of ultrasound propagation and attenuation at fixed frequency in low …
Static Magnetic Field
W Qiu, J Zhang, Y Luo, X Han - Authorea Preprints, 2023 - techrxiv.org
Ultrasonic measurements at high magnetic field and low temperature necessitate ultra-fast
excitations, ultra-high dynamic range of duty-cycle adjustments, as well as real-time, precise …
excitations, ultra-high dynamic range of duty-cycle adjustments, as well as real-time, precise …