[LLIBRE][B] Measurement and detection of radiation
N Tsoulfanidis, S Landsberger - 2021 - taylorfrancis.com
As useful to students and nuclear professionals as its popular predecessors, this fifth edition
provides the most up-to-date and accessible introduction to radiation detector materials …
provides the most up-to-date and accessible introduction to radiation detector materials …
[HTML][HTML] Effect of Si and Nb additions on carbonitride coatings under proton irradiation: A comprehensive analysis of structural, mechanical, corrosion, and neutron …
In the present study, understoichiometric TiZrCN, TiZrNbCN, and TiZrSiCN coatings were
produced using the cathodic arc technique with a C/N ratio of approximately 0.5 to …
produced using the cathodic arc technique with a C/N ratio of approximately 0.5 to …
Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector
GSC Joel, NM Maurice, NME Jilbert… - Journal of …, 2018 - Elsevier
The combination of gamma-ray spectrometry, the development of related Monte Carlo
method and the GEANT4 (GEometry ANd Tracking) toolkit have been developed for gamma …
method and the GEANT4 (GEometry ANd Tracking) toolkit have been developed for gamma …
A high-efficiency HPGe coincidence system for environmental analysis
Abstract The Comprehensive Nuclear–Test–Ban Treaty (CTBT) is supported by a network of
certified laboratories which must meet certain sensitivity requirements for CTBT relevant …
certified laboratories which must meet certain sensitivity requirements for CTBT relevant …
A phoswich design using real-time rise time discrimination for Compton suppression of LaBr3: Ce detector
HD Wang, JB Lu, RP Li, TJ Gao, C Li, H Qu… - Nuclear Instruments and …, 2023 - Elsevier
As one of the detectors with superior performances, the Compton continuum in the spectra of
the Cerium-doped Lanthanum 3-Bromide (LaBr 3: Ce) detector should be suppressed for …
the Cerium-doped Lanthanum 3-Bromide (LaBr 3: Ce) detector should be suppressed for …
Monte-Carlo optimisation of a Compton suppression system for use with a broad-energy HPGe detector
Monte-Carlo simulations are used to evaluate and optimise multiple components of a
Compton Suppression System based upon a Broad-energy HPGe primary detector. Several …
Compton Suppression System based upon a Broad-energy HPGe primary detector. Several …
Compton suppressed gamma-spectrometry for comprehensive nuclear-test-ban treaty samples
Abstract The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a network of
certified laboratories that perform high-resolution gamma-spectrometry on global air filter …
certified laboratories that perform high-resolution gamma-spectrometry on global air filter …
Improving the effectiveness of a low-energy Compton suppression system
A novel method for collecting and processing coincidence data from a Compton Suppressed
Low Energy Photon Spectrometer (LEPS) is presented, greatly simplifying the current setup …
Low Energy Photon Spectrometer (LEPS) is presented, greatly simplifying the current setup …
Characterisation of a SAGe well detector using GEANT4 and LabSOCS
This paper reports on the performance of a recently developed Small Anode Germanium
(SAGe) well detector from Canberra Industries. This has been specifically designed to …
(SAGe) well detector from Canberra Industries. This has been specifically designed to …
Preliminary simulations of NaI (Tl) detectors, and coincidence analysis using event stam**
This paper discusses preliminary work into the modelling and processing of coincidence
measurements, for which a Monte-Carlo simulation and a post-processing program have …
measurements, for which a Monte-Carlo simulation and a post-processing program have …