A step towards standardising accelerated corrosion tests on laboratory reinforced concrete specimens
Natural steel corrosion of reinforced concrete (RC) structures is a slow process which
researchers find necessary to accelerate in laboratory tests to obtain needed damage in a …
researchers find necessary to accelerate in laboratory tests to obtain needed damage in a …
[HTML][HTML] Analytical assessment of the bearing capacity of RC beams with corroded steel bars beyond concrete cover cracking
GG Triantafyllou, TC Rousakis, AI Karabinis - Composites Part B …, 2017 - Elsevier
Corrosion of steel reinforcement is one of the major causes that limit durability and
serviceability performance of reinforced concrete (RC) structures. This paper reviews …
serviceability performance of reinforced concrete (RC) structures. This paper reviews …
[HTML][HTML] Experimental study of FRP-strengthened concrete beams with corroded reinforcement
Corrosion of steel reinforcement is the major cause of deterioration in reinforced concrete
structures. Strengthening of concrete structures has been widely studied. However, most …
structures. Strengthening of concrete structures has been widely studied. However, most …
Corrosion-induced cracking and bond strength in reinforced concrete
Corrosion of the steel reinforcement is among the main causes of deterioration in concrete
structures. Measures of corrosion levels are typically used to evaluate the subsequent …
structures. Measures of corrosion levels are typically used to evaluate the subsequent …
Corroded reinforced concrete columns under simulated seismic loading
An experimental study was conducted to examine the effects of corrosion for seismic
performance of reinforced concrete (RC) columns confirming to current seismic guidelines …
performance of reinforced concrete (RC) columns confirming to current seismic guidelines …
Investigation on CFRP as dual-functional material in chloride-contaminated solutions
This paper investigates the performance of carbon fibre reinforced polymer (CFRP) as a
dual function material in combined impressed current cathodic protection and structural …
dual function material in combined impressed current cathodic protection and structural …
Simulation of shear behavior of corroded reinforced concrete beams flexurally repaired with steel fiber-reinforced concrete
The finite element (FE) method is a common and convenient tool for simulating the
behaviors of reinforced concrete (RC) beams. However, the applicability of the FE method …
behaviors of reinforced concrete (RC) beams. However, the applicability of the FE method …
Corroded RC beams at service load before and after patch repair and strengthening with NSM CFRP strips
G Triantafyllou, T Rousakis, A Karabinis - Buildings, 2019 - mdpi.com
This paper presents the experimental results of the structural behavior of four reinforced
concrete beams with corroded steel reinforcement at service loads. One beam was non …
concrete beams with corroded steel reinforcement at service loads. One beam was non …
Effect of combined pre-cracking and corrosion on the method of repair of concrete beams
This study investigated the combined effect of pre-cracking and corrosion on repair methods
of reinforced concrete beams. The experimental program consisted of prismatic pre-cracked …
of reinforced concrete beams. The experimental program consisted of prismatic pre-cracked …
Assessment of shear resistance of corroded beams repaired using SFRC in the tension zone
P Jongvivatsakul, P Laopaitoon… - Computers and …, 2021 - koreascience.kr
This study experimentally and analytically investigates the shear behavior of corroded
reinforced concrete (RC) beams repaired using steel fiber-reinforced concrete (SFRC) in the …
reinforced concrete (RC) beams repaired using steel fiber-reinforced concrete (SFRC) in the …