Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Complete characterization of ultrafast optical fields by phase-preserving nonlinear autocorrelation
Nonlinear autocorrelation was one of the earliest and simplest tools for obtaining partial
temporal information about an ultrashort optical pulse by gating it with itself. However, since …
temporal information about an ultrashort optical pulse by gating it with itself. However, since …
A static Fourier‐transform spectrometer based on Wollaston prisms
A static Fourier‐transform spectrometer has been designed based on Wollaston prisms. It
produces an interferogram in the spatial domain which is recorded using a 2D camera. A …
produces an interferogram in the spatial domain which is recorded using a 2D camera. A …
Room‐Temperature, High‐SNR Upconversion Spectrometer in the 6–12 µm Region
Abstract Mid‐infrared (MIR) spectroscopy, which has important applications in medicine,
environmental monitoring, materials, and food science, is widely performed using Fourier …
environmental monitoring, materials, and food science, is widely performed using Fourier …
Design of a static Fourier-transform spectrometer with increased field of view
We present several novel designs of static Fourier-transform spectrometers based on
Wollaston prisms. By numerical modeling we show the increased field of view that can be …
Wollaston prisms. By numerical modeling we show the increased field of view that can be …
Analysis and design of modified Wollaston prisms
CC Montarou, TK Gaylord - Applied optics, 1999 - opg.optica.org
An exact analysis of the working parameters of a modified Wollaston prism is presented.
Parameters include the output splitting angle, the retardation, and the location of the plane of …
Parameters include the output splitting angle, the retardation, and the location of the plane of …
High-performance nonscanning Fourier-transform spectrometer that uses a Wollaston prism array
D Komisarek, K Reichard, D Merdes, D Lysak, P Lam… - Applied …, 2004 - opg.optica.org
A high-performance nonscanning Fourier-transform spectrometer is reported that is
composed mainly of a Wollaston prism array and a two-dimensional photodetector array. It is …
composed mainly of a Wollaston prism array and a two-dimensional photodetector array. It is …
Spatial heterodyne interferometry with<? A3B2 show [pmg: line-break justify=" yes"/]?> polarization gratings
The implementation of a polarization-based spatial heterodyne interferometer (SHI) is
described. While a<? A3B2 show [pmg: line-break justify=" yes"/]?> conventional SHI uses a …
described. While a<? A3B2 show [pmg: line-break justify=" yes"/]?> conventional SHI uses a …
Near-field imaging for single-shot waveform measurements
The accurate measurement of ultrashort pulses is necessary to optimize pulse compression
for nonlinear optics and strong-field physics. Additionally, field-sensitive time-domain …
for nonlinear optics and strong-field physics. Additionally, field-sensitive time-domain …
Exact calculation of the optical path difference and description of a new birefringent interferometer
S Prunet, BA Journet, G Fortunato - Optical Engineering, 1999 - spiedigitallibrary.org
A new Fourier transform spectrometer is presented. The novelty of this work comes from the
interferometer designed with two identical Wollaston prisms. Thus, the interferogram, formed …
interferometer designed with two identical Wollaston prisms. Thus, the interferogram, formed …
Conditional-sampling spectrograph detection system for fluorescence measurements of individual airborne biological particles
P Nachman, G Chen, RG Pinnick, SC Hill, RK Chang… - Applied …, 1996 - opg.optica.org
We report the design and operation of a prototype conditional-sampling spectrograph
detection system that can record the fluorescence spectra of individual, micrometer-sized …
detection system that can record the fluorescence spectra of individual, micrometer-sized …