Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[PDF][PDF] Optimal overcurrent relays coordination in the presence multi tcsc on power systems using BBO algorithm
Optimal coordination of Inverse Definite Minimum Time (IDMT) direction overcurrent relays
in the power systems in the presence of multiple Thyristor Controller Series Capacitor …
in the power systems in the presence of multiple Thyristor Controller Series Capacitor …
[PDF][PDF] A comparative study of gcsc and tcsc effects on mho distance relay setting in algerian transmission line
This paper presents a comparative study of the performance of distance relays for
transmission line high voltage (HV) 400 kV in Eastern Algerian transmission networks at …
transmission line high voltage (HV) 400 kV in Eastern Algerian transmission networks at …
[PDF][PDF] Impact of apparent reactance injected by TCSR on distance relay in presence phase to earth fault
This research paper presents the impact study of apparent reactance injected by series
Flexible AC Transmission System (FACTS) ie Thyristor Controlled Series Reactor (TCSR) on …
Flexible AC Transmission System (FACTS) ie Thyristor Controlled Series Reactor (TCSR) on …
[PDF][PDF] A comparative study of impact series FACTS devices on distance relay setting in 400 kV Transmission Line
This research paper presents a comparative study of the performance of distance protection
for transmission line 400 kV in Algerian transmission networks at Group Sonelgaz (Algerian …
for transmission line 400 kV in Algerian transmission networks at Group Sonelgaz (Algerian …
A comparative study of ground fault analysis for a practical case of a transmission line equipped with different series FACTS devices
Due to the rising power demand and increasing population worldwide, electrical power
networks have been extensively growing and striving to satisfy the escalating loads. This …
networks have been extensively growing and striving to satisfy the escalating loads. This …
Bibliography of FACTS: 2006–2007 Part I IEEE working group report
This paper presents a Bibliography of FACTS technology mainly for the year 2007. Papers
published/presented in Conferences in later part of 2006, which appeared on search …
published/presented in Conferences in later part of 2006, which appeared on search …
[PDF][PDF] Impact of TCSC on distance protection setting based modified particle swarm optimization techniques
This paper presents the application of the Modified Particle Swarm Optimization (MPSO)
technique for optimal settings zones for MHO distance relay protect 400 kV single …
technique for optimal settings zones for MHO distance relay protect 400 kV single …
[PDF][PDF] Optimal Placement of TCSC to Improve Voltage Stability Limit Considering Impacts on Setting Zones of Distance Protection Relays
Voltage stability problems have been responsible for several major blackouts that have
been experienced in many countries. Reactive power limit of power system is one of the …
been experienced in many countries. Reactive power limit of power system is one of the …
[PDF][PDF] MODIFIED SETTING NUMERICAL DISTANCE PROTECTION OF POWER TRANSMISSION LINE IN PRESENCE TCSC USING IEC 62850 COMMUNICATION …
This paper presents a study of the performance of numerical distance relay for a 400 kV
electrical transmission line compensated by series Flexible AC Transmission System …
electrical transmission line compensated by series Flexible AC Transmission System …
[PDF][PDF] „Impact of Fault Resistance on Transmission Line Compensated by Series FACTS Devices‟
M Zellagui, A Chaghi, H Hassan, A Ghodbane… - … and Automatic Control … - researchgate.net
Flexible AC Transmission System (FACTS) devices, namely the Thyristor Controlled Series
Capacitor (TCSC), GTO Controlled Series Capacitor (GCSC) and Thyristor Controlled Series …
Capacitor (TCSC), GTO Controlled Series Capacitor (GCSC) and Thyristor Controlled Series …