Search for neutrinoless double- decay in with 26 kg yr of exposure from the Majorana Demonstrator

SI Alvis, IJ Arnquist, FT Avignone III, AS Barabash… - Physical Review C, 2019 - APS
The Majorana Collaboration is operating an array of high-purity Ge detectors to search for
the neutrinoless double-β decay of Ge 76. The Majorana Demonstrator consists of 44.1 kg of …

ADC Nonlinearity Correction for the Majorana Demonstrator

N Abgrall, JM Allmond, IJ Arnquist… - … on Nuclear Science, 2020 - ieeexplore.ieee.org
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal
digitization requirements demand both wide dynamic range and high resolution, as is the …

A histogram-based testing method for estimating A/D converter performance

HW Ting, BD Liu, SJ Chang - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
A sine-wave histogram-testing structure for analog-to-digital converters (ADCs) is proposed.
The ADC static parameters, ie, offset error, gain error, and nonlinearity errors, are directly …

A comparison of least squares and maximum likelihood methods using sine fitting in ADC testing

J Šaliga, I Kollár, L Michaeli, J Buša, J Lipták… - Measurement, 2013 - Elsevier
ADC test methods require the best possible reconstruction of the input signal of the ADC
under test from the acquired, therefore erroneous, ADC output data. The commonly used …

Normalized frequency estimation for accurate dynamic characterization of A/D converters by means of the three-parameters sine-fit algorithm

D Belega, D Dallet - Measurement, 2008 - Elsevier
In this paper an accurate estimation procedure of the effective number of bits (ENOB) of an
analog-to-digital converter (ADC) by means of the three-parameter sine-fit algorithm is …

A low power and low signal 5-bit 25 MS/s pipelined ADC for monolithic active pixel sensors

J Bouvier, M Dahoumane, D Dzahini… - … on Nuclear Science, 2007 - ieeexplore.ieee.org
For CMOS monolithic active pixels sensor readout, we developed a 5 bit low power analog
to digital converter using a pipelined architecture. A non-resetting sample and hold stage is …

Development of an USB data acquisition system for power quality and smart metering applications

M Caciotta, S Giarnetti, F Leccese… - 2012 11th International …, 2012 - ieeexplore.ieee.org
Starting from a previous work, a new Data Acquisition USB Device has been designed,
developed, realized and characterized to be used in Power Quality and Smart Grid …

Phase estimation of asynchronously sampled signal using interpolated three-parameter sinewave fit technique

R Lapuh - 2010 IEEE Instrumentation & Measurement …, 2010 - ieeexplore.ieee.org
This paper proposes an interpolated three-parameter sinewave fit method for estimating
asynchronously sampled signal phase. The proposed method provides improved phase …

Sensitivity to frequency uncertainty of the estimators provided by the two-parameter sine-fit algorithm

D Belega, D Petri - IEEE Transactions on Instrumentation and …, 2021 - ieeexplore.ieee.org
In this article, the contribution of frequency error on the sine-wave amplitude and phase
estimators returned by the linear two-parameter sine-fit (2PSF) algorithm is analyzed …

Dynamic testing of A/D converters by means of the three-parameter sine-fit algorithm

D Belega, D Dallet - Measurement, 2007 - Elsevier
The performances of the three-parameter sine-fit algorithm depend upon normalized
frequency accuracy. In this paper a constraint for the absolute error of the normalized …