Electronic temperatures, densities, and plasma x-ray emission of a 14.5 GHz electron-cyclotron resonance ion source

A Gumberidze, M Trassinelli, N Adrouche… - Review of Scientific …, 2010 - pubs.aip.org
We have performed a systematic study of the bremsstrahlung emission from the electrons in
the plasma of a commercial 14.5 GHz electron-cyclotron resonance ion source. The …

Stereochemical analysis of ferrocene and the uncertainty of fluorescence XAFS data

CT Chantler, NA Rae, MT Islam, SP Best… - Journal of …, 2012 - journals.iucr.org
Methods for the quantification of statistically valid measures of the uncertainties associated
with X-ray absorption fine structure (XAFS) data obtained from dilute solutions using …

Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of molybdenum over the  …

MD de Jonge, CQ Tran, CT Chantler, Z Barnea… - Physical Review A …, 2005 - APS
We use the x-ray extended-range technique (XERT)[Chantler, Phys. Rev. A 64, 062506
(2001)] to measure the mass attenuation coefficients of molybdenum in the x-ray energy …

Measurement of the x-ray mass attenuation coefficient of silver using the x-ray-extended range technique

CQ Tran, CT Chantler, Z Barnea… - Journal of Physics B …, 2004 - iopscience.iop.org
We used the x-ray-extended range technique to measure the x-ray mass attenuation
coefficients of silver in the 15–50 keV energy range with a level of uncertainty between …

X-ray mass attenuation coefficient of silicon: theory versus experiment

CQ Tran, CT Chantler, Z Barnea - Physical review letters, 2003 - APS
We compare new experimental x-ray total mass attenuation coefficients of silicon obtained
with the x-ray extended-range technique (XERT) from 5 to 20 keV with theoretical …

Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of tin over the energy range of

MD de Jonge, CQ Tran, CT Chantler, Z Barnea… - Physical Review A …, 2007 - APS
We use the x-ray extended-range technique (XERT)[CT Chantler, Phys. Rev. A 64, 062506
(2001)] to measure the mass attenuation coefficients of tin in the x-ray energy range of 29 …

[PDF][PDF] Propagation of uncertainty in experiment: structures of Ni (II) coordination complexes

MJ Schalken, CT Chantler - Journal of Synchrotron Radiation, 2018 - journals.iucr.org
Accurate experimental XAFS (X-ray absorption fine-structure) data including uncertainties
are required during analysis for valid comparison of results and conclusions of hypothesis …

Studies on effective atomic numbers and electron densities of nucleobases in DNA

A Kumar - Radiation Physics and Chemistry, 2016 - Elsevier
Various parameters of dosimetric importance such as effective atomic numbers (Z eff) and
electron densities (N el) of nucleobases in DNA have been calculated for the total and …

High accuracy determination of photoelectric cross sections, X-ray absorption fine structure and nanostructure analysis of zinc selenide using the X-ray extended …

D Sier, GP Cousland, RM Trevorah… - Journal of …, 2020 - journals.iucr.org
Measurements of mass attenuation coefficients and X-ray absorption fine structure (XAFS) of
zinc selenide (ZnSe) are reported to accuracies typically better than 0.13%. The high …

Absolute determination of the effect of scattering and fluorescence on x-ray attenuation measurements

CQ Tran, MD De Jonge, Z Barnea… - Journal of Physics B …, 2004 - iopscience.iop.org
We investigate the effect of x-ray scattering and fluorescence upon measurements of the x-
ray mass attenuation coefficient. Measurements of scattering and fluorescence are obtained …