Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A physiological control system for ECG-synchronized pulsatile pediatric ventricular assist devices
Ventricular assist devices (VADs) are mechanical pumps used to provide support to the
circulatory system of patients with ventricular dysfunction that are waiting for heart …
circulatory system of patients with ventricular dysfunction that are waiting for heart …
A mechanistic lumped parameter model of the Berlin Heart EXCOR to analyze device performance and physiologic interactions
Abstract Purpose The Berlin Heart EXCOR (BH) is the only FDA-approved, extracorporeal
pulsatile ventricular assist device (VAD) for infants and children with heart failure. Clinicians …
pulsatile ventricular assist device (VAD) for infants and children with heart failure. Clinicians …
Robust Control of Pulsatile Ventricular Assist Devices for Patients with Advanced Heart Failure
In this work, a robust control scheme has been developed for pulsatile left ventricular assist
devices (LVADs) used for advanced heart failure patients, utilizing the sliding mode control …
devices (LVADs) used for advanced heart failure patients, utilizing the sliding mode control …
Physiological Control of Pulsatile and Rotary Pediatric Ventricular Assist Devices
Several control strategies have been proposed to achieve physiological adaptation of
ventricular assist devices (VADs). This paper presents physiological control systems for …
ventricular assist devices (VADs). This paper presents physiological control systems for …
Sistema de controle fisiológico para bombas de sangue rotativas.
TR MELO, TR MELO - 2020 - dspace.sti.ufcg.edu.br
Neste trabalho trata-se do projeto e da implementação de um sistema de controle fisiológico
para bombas de sangue rotativas utilizadas como dispositivos de assistência ventricular. O …
para bombas de sangue rotativas utilizadas como dispositivos de assistência ventricular. O …
[PDF][PDF] A mathematical model that allows the representation of the regurgitation flow of a prosthetic cardiac valve
This work proposes a lumped parameter model (0D) for biological prosthetic heart valves
which represents the flow regurgitation. This model is used to obtain a more precise model …
which represents the flow regurgitation. This model is used to obtain a more precise model …
Uma contribuição à modelagem e estimação de parâmetros de válvulas cardíaca.
FJS VASCONCELOS - 2019 - dspace.sti.ufcg.edu.br
Neste trabalho é proposto um modelo a parâmetros concentrados (0D) de próteses de
válvulas cardíacas biológicas a fim de se obter um modelo mais preciso de um dispositivo …
válvulas cardíacas biológicas a fim de se obter um modelo mais preciso de um dispositivo …