Modeling strategies for the computational analysis of unreinforced masonry structures: review and classification
Masonry structures, although classically suitable to withstand gravitational loads, are
sensibly vulnerable if subjected to extraordinary actions such as earthquakes, exhibiting …
sensibly vulnerable if subjected to extraordinary actions such as earthquakes, exhibiting …
Uses and limits of the Equivalent Frame Model on existing unreinforced masonry buildings for assessing their seismic risk: A review
Since the late 1970s, nonlinear static analysis have had an increasing use in the seismic
assessment of existing unreinforced masonry (URM) buildings. Different modelling …
assessment of existing unreinforced masonry (URM) buildings. Different modelling …
Performance of brick-filled reinforced concrete composite wall strengthened with C-FRP laminate (s) under blast loading
From the safety of the structure and security point of view, the role of free-standing
compound wall is still relevant. Such unreinforced walls have limited flexural capacity under …
compound wall is still relevant. Such unreinforced walls have limited flexural capacity under …
Non-linear dynamic and static analyses on eight historical masonry towers in the North-East of Italy
M Valente, G Milani - Engineering Structures, 2016 - Elsevier
The behavior of eight historical masonry towers, located in the North-East region of Italy, is
analyzed under horizontal loads by means of detailed 3D FE models. The geometry of the …
analyzed under horizontal loads by means of detailed 3D FE models. The geometry of the …
Strengthening of braced unreinforced brick masonry wall with (i) C-FRP wrap**, and (ii) steel angle-strip system under blast loading
Accidental detonations, and explosions made by extremists are major threats to human life
and building structures. The vulnerability of the load-bearing masonry structures is more as …
and building structures. The vulnerability of the load-bearing masonry structures is more as …
An innovative numerical modeling strategy for the structural analysis of historical monumental buildings
In this paper, an innovative numerical modeling strategy for the structural analysis of
historical monumental buildings is presented. The strategy is based on a procedure that …
historical monumental buildings is presented. The strategy is based on a procedure that …
Performance of masonry heritage building under air-blast pressure without and with ground shock
In general, the blast-induced ground shock excites the foundation of the structure prior to the
air-blast pressure because of the obvious reasons of difference in wave propagation …
air-blast pressure because of the obvious reasons of difference in wave propagation …
Assessment of a monumental masonry bell-tower after 2016 Central Italy seismic sequence by long-term SHM
The response of the San Pietro monumental bell-tower located in Perugia, Italy, to the 2016
Central Italy seismic sequence is investigated, taking advantage of the availability of field …
Central Italy seismic sequence is investigated, taking advantage of the availability of field …
Temperature effects on static and dynamic behavior of Consoli Palace in Gubbio, Italy
In recent years, the development of long-term structural health monitoring systems for
preventive conservation of historic monumental buildings is receiving a growing trend of …
preventive conservation of historic monumental buildings is receiving a growing trend of …
A study on existing masonry heritage building to explosive-induced blast loading and its response
In the present study, explicit dynamic analysis has been conducted to investigate the blast
response of the masonry heritage building, located in the southern part of Asia, subjected to …
response of the masonry heritage building, located in the southern part of Asia, subjected to …