[HTML][HTML] On the design evolution of hip implants: A review
This manuscript reviews the development of femoral stem prostheses in the biomedical field.
After a brief introduction on the development of these prostheses and the associated …
After a brief introduction on the development of these prostheses and the associated …
Femoral stems with porous lattice structures: a review
Cementless femoral stems are prone to stress shielding of the femoral bone, which is
caused by a mismatch in stiffness between the femoral stem and femur. This can cause …
caused by a mismatch in stiffness between the femoral stem and femur. This can cause …
Damage-programmable design of metamaterials achieving crack-resisting mechanisms seen in nature
The fracture behaviour of artificial metamaterials often leads to catastrophic failures with
limited resistance to crack propagation. In contrast, natural materials such as bones and …
limited resistance to crack propagation. In contrast, natural materials such as bones and …
Additive manufacture of ultrasoft bioinspired metamaterials
The dynamic loading behavior of materials plays a vital role in various engineering
applications, such as aerospace protective components, armor, marine infrastructures, and …
applications, such as aerospace protective components, armor, marine infrastructures, and …
Comparative analysis and experimental validation of statistical and machine learning-based regressors for modeling the surface roughness and mechanical …
This article analyzes the surface roughness and mechanical properties of 316L samples
produced by Selective Laser Melting (SLM) through the application of statistical regression …
produced by Selective Laser Melting (SLM) through the application of statistical regression …
A novel hybrid design and modelling of a customised graded Ti-6Al-4V porous hip implant to reduce stress-shielding: An experimental and numerical analysis
Stress shielding secondary to bone resorption is one of the main causes of aseptic
loosening, which limits the lifespan of hip prostheses and exacerbates revision surgery …
loosening, which limits the lifespan of hip prostheses and exacerbates revision surgery …
[HTML][HTML] Bioinspired porous hip implants design: a systematic review of mechanical testing and additive manufacturing
NNAA Abdullah, MI Ammarullah, ZF Salaha… - Results in …, 2024 - Elsevier
In clinical practice, the current medical device for total hip arthroplasty is made of a solid
structural material. Unfortunately, stress shielding is developed as a result of the materials …
structural material. Unfortunately, stress shielding is developed as a result of the materials …
Selective laser melting and spark plasma sintering: a perspective on functional biomaterials
Achieving lightweight, high-strength, and biocompatible composites is a crucial objective in
the field of tissue engineering. Intricate porous metallic structures, such as lattices, scaffolds …
the field of tissue engineering. Intricate porous metallic structures, such as lattices, scaffolds …
Topology optimisation for compliant hip implant design and reduced strain shielding
N Tan, RJ van Arkel - Materials, 2021 - mdpi.com
Stiff total hip arthroplasty implants can lead to strain shielding, bone loss and complex
revision surgery. The aim of this study was to develop topology optimisation techniques for …
revision surgery. The aim of this study was to develop topology optimisation techniques for …
Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review
Background Total joint replacements are an established treatment for patients suffering from
reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress …
reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress …