Comparison between inductive and resistive SFCL in terms of current limitation and power system transient stability

G Didier, CH Bonnard, T Lubin, J Lévêque - Electric Power Systems …, 2015 - Elsevier
In this paper, authors present a comparative study of inductive and resistive
superconducting fault current limiters (SFCL) from current limitation and power system …

Feasible application study of several types of superconducting fault current limiters in HVDC grids

HY Lee, M Asif, KH Park, BW Lee - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC
grids. One of the key obstacles in realization of the HVDC grid is the absence of a dc circuit …

[HTML][HTML] Application of resistive super conductor fault current limiter for protection of grid-connected DGs

AY Hatata, AS Ebeid, MM El-Saadawi - Alexandria engineering journal, 2018 - Elsevier
Abstract Penetration of Distributed Generation (DG) into the power system causes technical
problems and bad effects on the safety of the system due to increasing the short circuit levels …

DC current limiting operation and power burden characteristics of a flux-coupling type SFCL connected in series between two windings

SC Ko, TH Han, SH Lim - Electronics, 2021 - mdpi.com
In this paper, a DC fault short circuit was conducted to analyze the DC fault current limiting
characteristics of a flux-coupling type superconducting fault current limiter (SFCL) that has …

Shortening recovery time with bypass breaker for resistive superconductor fault current limiters

B Yilmaz, MT Gencoglu - Arabian Journal for Science and Engineering, 2023 - Springer
Many modern limiting methods have been developed for power systems in recent years.
Resistive superconductor fault current limiter (R-SFCL), one of the modern limiting methods …

Power flow analysis and optimal locations of resistive type superconducting fault current limiters

X Zhang, HS Ruiz, J Geng, B Shen, L Fu, H Zhang… - SpringerPlus, 2016 - Springer
Based on conventional approaches for the integration of resistive-type superconducting fault
current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the …

Implementation of resistive type superconducting fault current limiters in electrical grids: Performance analysis and measuring of optimal locations

X Zhang, HS Ruiz, Z Zhong, TA Coombs - arxiv preprint arxiv:1508.01162, 2015 - arxiv.org
In the past few years there has been a significant rise in the short-circuit current levels in
transmission and distribution networks, it due to the increasing demands on power and the …

Analysing faults and SFCL response in electric aircraft

H Alafnan, X Zeng, X Pei, M Khedr… - Journal of Physics …, 2020 - iopscience.iop.org
Aircraft technology moves towards electrification in order to achieve environmentally friendly
goals. However, one of the main challenges facing the electrification of aircraft technology is …

Appropriate protection scheme for DC grid based on the half bridge modular multilevel converter system

HY Lee, M Asif, KH Park, HM Mun, BW Lee - Energies, 2019 - mdpi.com
The half bridge (HB) modular multilevel converter (MMC) technology is considered a
breakthrough to mitigate the shortcomings of the conventional voltage source converter …

Multicriteria decision approach for selection of fault current limiters technology

HB Tambunan, PAA Pramana… - 2019 Asia Pacific …, 2019 - ieeexplore.ieee.org
Java Bali power grid become larger because of continous development of power plant. In
the other hand, higher power generation leads to higher short circuit current level. One of the …