[BUKU][B] The Electrical Engineering Handbook-Six Volume Set

RC Dorf - 2018 - books.google.com
In two editions spanning more than a decade, The Electrical Engineering Handbook stands
as the definitive reference to the multidisciplinary field of electrical engineering. Our …

Induced voltage measurements on an experimental distribution line during nearby rocket triggered lightning flashes

PP Barker, TA Short, AR Eybert-Berard… - … on Power Delivery, 1996 - ieeexplore.ieee.org
Rocket triggered lightning flashes were triggered near a de-energized experimental
distribution line while simultaneous measurements of the induced phase to neutral voltage …

Lightning-induced voltages on overhead lines—Application of the extended rusck model

A Piantini, JM Janiszewski - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
Lightning-induced overvoltages have a considerable impact on the power quality of
overhead distribution and telecommunications systems, and various models have been …

Observation of induced voltage at the terminal of 10 kV distribution line by nearby triggered lightning

J Wang, S Wang, L Cai, D Lu, Q Li… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
This paper presents the induced voltage measured at the terminal of a 10 kV distribution line
when triggered lightning taking place at a distance of 40 m. It is shown that the induced …

Evaluation of lightning-induced voltages on multiconductor overhead lines located above a lossy dispersive ground

K Sheshyekani, M Akbari - IEEE transactions on power delivery, 2013 - ieeexplore.ieee.org
The paper presents a comprehensive study on the effect of soil dispersion (ie, frequency
dependence of soil conductivity and relative permittivity) on the lightning-induced voltages …

Voltages induced on overhead lines by dart leaders and subsequent return strokes in natural and rocket-triggered lightning

F Rachidi, M Rubinstein, S Guerrieri… - IEEE Transactions on …, 1997 - ieeexplore.ieee.org
The voltages induced by nearby lightning strikes are a major cause of outages in power
distribution systems. We compute such voltages taking into account the effects of the dart …

Voltage induced on a test distribution line by negative winter lightning strokes to a tall structure

K Michishita, M Ishii, A Asakawa… - IEEE transactions on …, 2003 - ieeexplore.ieee.org
Simultaneous measurements of lightning-induced voltages and lightning currents are
presented and subject to analysis. The lightning current was measured at the top of a 200-m …

Experimental study of lightning-induced voltage on an overhead wire over lossy ground

M Ishii, K Michishita, Y Hongo - IEEE Transactions on …, 1999 - ieeexplore.ieee.org
Experiments on the lightning-induced voltage on an overhead wire with a simulated
lightning channel and a 1/20 reduced-scale model have been carried out on a lossy ground …

Influence of the ground potential rise on the residual voltage of low-voltage surge protective devices due to nearby lightning flashes

S Chen, Y Zhang, C Chen, X Yan… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
The characteristics of the residual voltage of a surge protective device (SPD) connected to
an overhead distribution line due to nearby natural cloud-to-ground lightning and to rocket …

Lightning electromagnetic fields and their induced voltages on overhead lines: The effect of a horizontally stratified ground

K Sheshyekani, J Paknahad - IEEE Transactions on Power …, 2014 - ieeexplore.ieee.org
The effect of a horizontally stratified two-layer ground on the aboveground lightning
electromagnetic (EM) fields at close, moderate, and far distances from the lightning channel …