Progressive collapse of steel structures exposed to fire: A critical review

Y Cao, J Jiang, Y Lu, W Chen, J Ye - journal of constructional steel research, 2023 - Elsevier
A state-of-the-art review is presented on design and research related to progressive
collapse of steel structures under fire conditions. The influence of load ratios, strength of …

Behaviour of stainless and high strength steel bolt assemblies at elevated temperatures—A review

MA Shaheen, ASJ Foster, LS Cunningham, S Afshan - Fire Safety Journal, 2020 - Elsevier
This study documents important aspects of bolt assembly performance in structural steel
connections at elevated temperatures that have not been the subject of detailed …

Experimental tests of different types of bolted steel beam–column joints under a central-column-removal scenario

B Yang, KH Tan - Engineering Structures, 2013 - Elsevier
Several structural collapse incidents indicate that failure usually started from beam–column
joints when exposed to abnormal loads. If the connections are sufficiently robust and there is …

[PDF][PDF] Structural fire engineering

O Salem, G Hadjisophocleous, E Zalok - 2020 - researchgate.net
In this paper, experimental results of the structural fire behaviour of four large-scale steel
frame test assemblies are presented. Test assemblies were made of HSS beams and …

[BOOK][B] Performance-based fire engineering of structures

Y Wang, I Burgess, F Wald, M Gillie - 2012 - books.google.com
Major events—notably the Broadgate fire in London, New York's World Trade Center
collapse, and the Windsor Tower fire in Madrid—as well as the enlightening studies at the …

Numerical analyses of steel beam–column joints subjected to catenary action

B Yang, KH Tan - Journal of Constructional Steel Research, 2012 - Elsevier
This paper presents the numerical results of 6 beam–column joint tests using six types of
connections: web cleat, fin plate, top and seat with web angles (TSWA)(8mm thick angle) …

Failure mechanism of steel frames with angle steel-bolted connections exposed to fire under progressive collapse condition

Y Zheng, W Zhong, Y Zhang, Z Tan, SC Duan… - Engineering Failure …, 2024 - Elsevier
Partially restrained connections comprise intricate systems of multiple components, each
exhibiting varying degrees of performance degradation under fire conditions. Consequently …

Thermal strength analysis of a steel bolted connection under bolt loss conditions

R Grzejda - Eksploatacja i Niezawodność, 2022 - yadda.icm.edu.pl
Steel bolted connections are used in many engineering, mechanical and building structures
that can be subjected to a wide variety of thermal loads [11, 28]. As a result of these loads …

Fire tests on full-scale steel portal frames against progressive collapse

G Lou, C Wang, J Jiang, Y Jiang, L Wang… - Journal of Constructional …, 2018 - Elsevier
This paper presents experimental investigations on the collapse behavior of a full-scale 36
m× 12 m steel portal frame exposed to natural fires. Extensive thermal and structural …

Behaviour of seismically damaged extended stiffened end-plate joints at elevated temperature

R Tartaglia, M D'Aniello, F Wald - Engineering Structures, 2021 - Elsevier
The mechanical features of beam-to-column joints may highly affect the resistance of steel
structures at elevated temperature. Therefore, the behaviour of steel joints under elevated …