Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Experimental and numerical investigations on the axial capacity of cold-formed steel built-up box sections
Built-up box sections are becoming increasingly popular for column members in cold-formed
steel (CFS) construction; uses of such sections include CFS trusses, space frames, and …
steel (CFS) construction; uses of such sections include CFS trusses, space frames, and …
Local buckling of steel members under fire conditions: a review
C Maraveas - Fire Technology, 2019 - Springer
Local buckling is a failure mode commonly observed in thin-walled structural steel elements.
Even though its effect on their behaviour at ambient temperature conditions is well …
Even though its effect on their behaviour at ambient temperature conditions is well …
An investigation on stiffened cold-formed steel unequal angle box section columns
Built-up box sections are gaining popularity as column members in cold-formed steel (CFS)
construction. Applications include CFS trusses, space frames, and portal frames. Two …
construction. Applications include CFS trusses, space frames, and portal frames. Two …
Numerical investigation on the composite action of cold-formed steel built-up battened columns
Cold-formed steel (CFS) built-up sections are widely used to achieve adequate load-bearing
capacity when individual shapes are not able to resist the design loads. In the existing …
capacity when individual shapes are not able to resist the design loads. In the existing …
[HTML][HTML] Influence of intermediate stiffeners on axial capacity of thin-walled built-up open and closed channel section columns
This paper investigates the post-buckling behaviour and axial capacity of thin-walled steel
stiffened single-channel sections (ISSCS) and back-to-back stiffened channel sections …
stiffened single-channel sections (ISSCS) and back-to-back stiffened channel sections …
Experimental and numerical study of an innovative 4-channels cold-formed steel built-up column under axial compression
This paper reports on experiments addressing the buckling and collapse behavior of an
innovative built-up cold formed steel (CFS) columns. The built-up column consists of four …
innovative built-up cold formed steel (CFS) columns. The built-up column consists of four …
[HTML][HTML] Full-scale tests of load-bearing LSF walls made of built-up CFS channel sections under fire conditions
Built-up cold-formed steel (CFS) studs, such as back-to-back channels (BC) and nested
channels (NC) are used in light gauge steel framed (LSF) wall systems instead of the …
channels (NC) are used in light gauge steel framed (LSF) wall systems instead of the …
[HTML][HTML] Structural fire performance of concrete-filled built-up cold-formed steel columns
Concrete-filled composite columns are widely used in the construction industry, exploiting
the benefits of combining steel and concrete, providing, for instance, high load-bearing …
the benefits of combining steel and concrete, providing, for instance, high load-bearing …
Screwed connections in built-up cold-formed steel members at ambient and elevated temperatures
Screwed connections are commonly used in fabricating built-up cold-formed steel (CFS)
members. However, the knowledge and understanding of their behaviour and design are …
members. However, the knowledge and understanding of their behaviour and design are …
Fire resistance of box-shape cold-formed steel built-up columns failing in global buckling: test, simulation and design
J Yang, X Zhou, W Wang, L Xu, Y Shi - Thin-Walled Structures, 2023 - Elsevier
Box-shape cold-formed steel built-up columns (CFS-QBC) are popular in multi-story CFS
buildings. This paper conducted experimental research, numerical simulation, and …
buildings. This paper conducted experimental research, numerical simulation, and …