Forced flow cryogenic cooling in fusion devices: A review

H Vaghela, VJ Lakhera, B Sarkar - Heliyon, 2021 - cell.com
The constantly increasing energy consumption along with the depleting fossil fuel resources
as well as owing to the fact that the nuclear fission not being an intrinsically safe method of …

Quantitative measurement of outgassing and degassing rate for various materials used in cryogenic pumps

SS Mukherjee, P Panchal, J Agarwal, P Nayak… - Materials Today …, 2018 - Elsevier
Outgassing from materials is a principal impediment for creating and maintaining clean and
ultrahigh-vacuum environments. Data about out-gassing rates of different materials is very …

Adsorption characteristic study of activated carbons down to 4.5 k

J Mishra, J Agarwal, S Kasthurirengan… - Materials Today …, 2018 - Elsevier
Adsorption characteristic study of different activated carbon samples are performed at low
temperature down to 5 K by using cryocooler based low temperature facility with a micropore …

System for adsorption isotherm studies of porous carbon materials down to 4.5 k

J Mishra, J Agarwal, S Mukherjee, P Nayak, P Panchal… - 2017 - indianjournals.com
In order to characterize different type of adsorbents for cryopum** specific application at
low temperature down to 4.5 K, a facility for adsorption study (FADS) is set up at Institute for …

Development of a control system for compression and expansion cycles of critical valve for high vacuum systems

J Agarwal, H Sharma, H Patel, R Gangradey… - Fusion Engineering and …, 2016 - Elsevier
A control system with feedback loop is designed, developed and tested to monitor the life
cycles of the axial valve and bellows used in vacuum valves. The control system monitors …

[PDF][PDF] THERMO-HYDRAULIC ANALYSIS OF FORCED FLOW HELIUM COOLED CRYOPANELS OF CRYOPUMP USING VENECIA CODE

SS MUKHERJEE, V GUPTA, R GANGRADEY… - 2018 - nucleus.iaea.org
Cryoadsorption cryopump with large pum** speeds application has been developed at
the Institute for Plasma Research (IPR). These pumps are cooled with liquid helium for …