Dynamic buckling and seismic fragility of anchored steel tanks by the added mass method

N Buratti, M Tavano - Earthquake Engineering & Structural …, 2014 - Wiley Online Library
Buckling plays a fundamental role in the design of steel tanks because of the small
thicknesses of the walls of this class of structures. The first part of the paper presents a …

Sloshing effect analysis of liquid storage tank under seismic excitation

D Luo, C Liu, J Sun, L Cui, Z Wang - Structures, 2022 - Elsevier
Sloshing wave height is a main parameter in the seismic design of liquid storage tanks, and
severe sloshing may lead to the liquid leakage or buckling of the steel tank wall. To …

Optimizing the seismic response of base-isolated liquid storage tanks using swarm intelligence algorithms

A Tsipianitis, Y Tsompanakis - Computers & Structures, 2021 - Elsevier
Large-scale liquid storage tanks are used worldwide for storing water, chemicals and fuels,
such as liquefied natural gas (LNG) and oil. Any major damage due to man-made or natural …

Seismic behaviour of isolated fluid storage tanks: A-state-of-the-art review

VR Panchal, DP Soni - KSCE Journal of Civil Engineering, 2014 - Springer
An updated state-of-the-art-review of the behaviour of the isolated fluid storage tanks to
seismic excitation is presented. The main objective of review is to provide assistance to …

Negative stiffness and inerter-based dampers: novel seismic response control approach for base isolated liquid storage tanks

NU Islam, RS Jangid - Structures, 2024 - Elsevier
Liquid storage tanks (LSTs) have become indispensable to civil engineering infrastructure.
LSTs are used not only for storing harmless fluids but also explosive, toxic, and hazardous …

Performance assessment of lead rubber–isolated liquid storage tanks with clutching inertial systems

KN Bajad, RS Jangid - ASCE-ASME Journal of Risk and Uncertainty …, 2024 - ascelibrary.org
Liquid storage tanks (LSTs)—lifeline structures—must remain functional after earthquake
events. Concerns regarding high sloshing and isolator displacement have led to the use of …

Variable friction pendulum system for near‐fault ground motions

VR Panchal, RS Jangid - … Monitoring: The Official Journal of the …, 2008 - Wiley Online Library
The seismic response of a flexible multi‐storey building isolated with variable friction
pendulum system (VFPS) is investigated under normal component of six near‐fault ground …

[HTML][HTML] Impact of dynamic soil–structure interaction on the response of liquid-storage tanks

A Tsipianitis, Y Tsompanakis… - Frontiers in Built …, 2020 - frontiersin.org
In general, soil-structure interaction phenomena affect considerably the dynamic response
of liquid-storage tanks. As it is also observed in the case of ordinary structures, the ground …

Performance of a force-restricted viscous mass damper incorporated into base-isolated liquid storage tanks

Z Tang, H Zhu, H Luo, T Li - Structures, 2024 - Elsevier
Base isolation systems have been widely used to protect large liquid storage tanks (LSTs)
from the damaging effect induced by strong earthquake events. In the previous study …

Seismic performance improvement of liquid storage tank based on base-isolation and pendulum tuned mass damper

W **g, J Feng, S Song, X Cheng - Nuclear Engineering and Design, 2024 - Elsevier
It is necessary to ensure the safety of liquid storage tanks under earthquakes, but the
damage probability of the non-dam** liquid storage tanks is higher under earthquakes …