Dynamic buckling and seismic fragility of anchored steel tanks by the added mass method
N Buratti, M Tavano - Earthquake Engineering & Structural …, 2014 - Wiley Online Library
Buckling plays a fundamental role in the design of steel tanks because of the small
thicknesses of the walls of this class of structures. The first part of the paper presents a …
thicknesses of the walls of this class of structures. The first part of the paper presents a …
Sloshing effect analysis of liquid storage tank under seismic excitation
D Luo, C Liu, J Sun, L Cui, Z Wang - Structures, 2022 - Elsevier
Sloshing wave height is a main parameter in the seismic design of liquid storage tanks, and
severe sloshing may lead to the liquid leakage or buckling of the steel tank wall. To …
severe sloshing may lead to the liquid leakage or buckling of the steel tank wall. To …
Optimizing the seismic response of base-isolated liquid storage tanks using swarm intelligence algorithms
A Tsipianitis, Y Tsompanakis - Computers & Structures, 2021 - Elsevier
Large-scale liquid storage tanks are used worldwide for storing water, chemicals and fuels,
such as liquefied natural gas (LNG) and oil. Any major damage due to man-made or natural …
such as liquefied natural gas (LNG) and oil. Any major damage due to man-made or natural …
Seismic behaviour of isolated fluid storage tanks: A-state-of-the-art review
VR Panchal, DP Soni - KSCE Journal of Civil Engineering, 2014 - Springer
An updated state-of-the-art-review of the behaviour of the isolated fluid storage tanks to
seismic excitation is presented. The main objective of review is to provide assistance to …
seismic excitation is presented. The main objective of review is to provide assistance to …
Negative stiffness and inerter-based dampers: novel seismic response control approach for base isolated liquid storage tanks
Liquid storage tanks (LSTs) have become indispensable to civil engineering infrastructure.
LSTs are used not only for storing harmless fluids but also explosive, toxic, and hazardous …
LSTs are used not only for storing harmless fluids but also explosive, toxic, and hazardous …
Performance assessment of lead rubber–isolated liquid storage tanks with clutching inertial systems
Liquid storage tanks (LSTs)—lifeline structures—must remain functional after earthquake
events. Concerns regarding high sloshing and isolator displacement have led to the use of …
events. Concerns regarding high sloshing and isolator displacement have led to the use of …
Variable friction pendulum system for near‐fault ground motions
VR Panchal, RS Jangid - … Monitoring: The Official Journal of the …, 2008 - Wiley Online Library
The seismic response of a flexible multi‐storey building isolated with variable friction
pendulum system (VFPS) is investigated under normal component of six near‐fault ground …
pendulum system (VFPS) is investigated under normal component of six near‐fault ground …
[HTML][HTML] Impact of dynamic soil–structure interaction on the response of liquid-storage tanks
A Tsipianitis, Y Tsompanakis… - Frontiers in Built …, 2020 - frontiersin.org
In general, soil-structure interaction phenomena affect considerably the dynamic response
of liquid-storage tanks. As it is also observed in the case of ordinary structures, the ground …
of liquid-storage tanks. As it is also observed in the case of ordinary structures, the ground …
Performance of a force-restricted viscous mass damper incorporated into base-isolated liquid storage tanks
Base isolation systems have been widely used to protect large liquid storage tanks (LSTs)
from the damaging effect induced by strong earthquake events. In the previous study …
from the damaging effect induced by strong earthquake events. In the previous study …
Seismic performance improvement of liquid storage tank based on base-isolation and pendulum tuned mass damper
W **g, J Feng, S Song, X Cheng - Nuclear Engineering and Design, 2024 - Elsevier
It is necessary to ensure the safety of liquid storage tanks under earthquakes, but the
damage probability of the non-dam** liquid storage tanks is higher under earthquakes …
damage probability of the non-dam** liquid storage tanks is higher under earthquakes …