Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A review on superhydrophobic surface with anti-icing properties in overhead transmission lines
B Li, J Bai, J He, C Ding, X Dai, W Ci, T Zhu, R Liao… - coatings, 2023 - mdpi.com
The icing on overhead transmission lines is one of the largest threats to the safe operation of
electric power systems. Compared with other security accidents in the electric industry, a …
electric power systems. Compared with other security accidents in the electric industry, a …
[HTML][HTML] Electricity grid resilience amid various natural disasters: Challenges and solutions
Electricity grid vulnerabilities can lead to outages with prolonged load interruptions.
Research activities on the impact of natural disasters on power system are underway to …
Research activities on the impact of natural disasters on power system are underway to …
Insulator flashover under icing conditions
M Farzaneh - IEEE Transactions on Dielectrics and Electrical …, 2014 - ieeexplore.ieee.org
Atmospheric ice accretion, combined with pollution, has been recognized as a significant
risk factor in the reliability of line and station insulators in cold climate regions. Flashovers …
risk factor in the reliability of line and station insulators in cold climate regions. Flashovers …
Insulator selection for AC overhead lines with respect to contamination
Insulator contamination remains an important technical problem because contamination-
caused insulator flashovers may jeopardize the security of high voltage power systems. This …
caused insulator flashovers may jeopardize the security of high voltage power systems. This …
Study on AC flashover performance and discharge process of polluted and iced IEC standard suspension insulator string
X Jiang, S Wang, Z Zhang, S ** and
power failure, which interfere with the normal operation of the power grid. Accordingly …
power failure, which interfere with the normal operation of the power grid. Accordingly …
Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 kV UHV AC transmission lines
J Hu, C Sun, X Jiang, Z Zhang… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
A method is introduced for testing insulators under icing conditions. The method is based on
and developed from those described in the standard of IEC60-1, IEC 60507 and IEEE Task …
and developed from those described in the standard of IEC60-1, IEC 60507 and IEEE Task …
[HTML][HTML] Discharge development process and flashover performance of snow-accreted insulators under natural environment
J Sun, Y Hu, X Jiang, Y Wu, T Li, Y Zhao… - International Journal of …, 2023 - Elsevier
The safe and reliable operation of power system in China is significantly affected by snow-
covered insulator. At present, many studies on snow-accreted insulator have been …
covered insulator. At present, many studies on snow-accreted insulator have been …
Reducing ice accumulation on insulators by applying semiconducting RTV silicone coating
W Liao, Z Jia, Z Guan, L Wang, J Yang… - … on Dielectrics and …, 2007 - ieeexplore.ieee.org
Ice accumulation on high voltage insulators can cause accidents by flashover across the ice-
covered insulators. The ice accumulation can be reduced by changing the insulator surface …
covered insulators. The ice accumulation can be reduced by changing the insulator surface …
DC flashover performance and effect of sheds configuration on polluted and ice–covered composite insulators at low atmospheric pressure
X Jiang, Y Chao, Z Zhang, J Hu… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
How to choose external insulation under high altitude, pollution and icing conditions for
UHVDC transmission project is a complicated problem. To provide technical reference to …
UHVDC transmission project is a complicated problem. To provide technical reference to …