Magnetic nanoparticles in cancer therapy and diagnosis
There is urgency for the development of nanomaterials that can meet emerging biomedical
needs. Magnetic nanoparticles (MNPs) offer high magnetic moments and surface‐area‐to …
needs. Magnetic nanoparticles (MNPs) offer high magnetic moments and surface‐area‐to …
MRI and dental implantology: two which do not exclude each other
P Korn, C Elschner, MC Schulz, U Range, R Mai… - Biomaterials, 2015 - Elsevier
Currently, histological techniques are used to analyse implant-tissue-interactions. However,
these methods are destructive and time-consuming. Furthermore, they require a large …
these methods are destructive and time-consuming. Furthermore, they require a large …
Diagnostic accuracy and confidence of [18F] FDG PET/MRI in comparison with PET or MRI alone in head and neck cancer
J Park, K Pak, TJ Yun, EK Lee, I Ryoo, JY Lee… - Scientific reports, 2020 - nature.com
The usefulness of PET/MRI in head and neck malignancy has not been fully elucidated. The
purpose of our study was to evaluate the diagnostic accuracy and confidence of PET/MRI in …
purpose of our study was to evaluate the diagnostic accuracy and confidence of PET/MRI in …
Known-component metal artifact reduction (KC-MAR) for cone-beam CT
Intraoperative cone-beam CT (CBCT) is increasingly used for surgical navigation and
validation of device placement. In spinal deformity correction, CBCT provides visualization of …
validation of device placement. In spinal deformity correction, CBCT provides visualization of …
Quantification of image artifacts from navigation markers in dynamic guided implant surgery and the effect on registration performance in different clinical scenarios.
Y Du, K Wangrao, L Liu, L Liu… - International Journal of …, 2019 - search.ebscohost.com
Purpose: Different navigation markers in dynamic guided implant surgery could cause
different degrees of artifacts, which would affect the accuracy and efficiency of the implant …
different degrees of artifacts, which would affect the accuracy and efficiency of the implant …
Joint metal artifact reduction and segmentation of CT images using dictionary-based image prior and continuous-relaxed potts model
Segmenting interesting objects from CT images has a wide range of applications. However,
to achieve good results, it is often necessary to apply metal artifact reduction to raw CT …
to achieve good results, it is often necessary to apply metal artifact reduction to raw CT …
Recent Trends in the Application of Materials for Cancer Therapy and Diagnosis
The application of nanomaterials has been expanded in various medical fields. One of these
important fields in the use of nanoparticles is cancer therapy and its diagnosis …
important fields in the use of nanoparticles is cancer therapy and its diagnosis …
Suppression of metal artefacts in CT using virtual singorams and corresponding MR images
Medical imaging is invaluable when it cornes to gaining insight into the human body. As is
well known, medical images need to deal with artefacts. This article presents a modern …
well known, medical images need to deal with artefacts. This article presents a modern …
Model-based image processing algorithms for CT image reconstruction, artifact reduction and segmentation
P ** - 2015 - search.proquest.com
Abstract Model-based image processing is a collection of techniques that provides a
systematic framework for solving inverse problems in imaging systems. In this dissertation …
systematic framework for solving inverse problems in imaging systems. In this dissertation …
Survey on Causes and Reduction of Metal Artifact in Medical Images
The diagnostic values of the scanned images are degraded by the presence of metallic
implants. These metallic implants are placed inside the human body due to the growth in …
implants. These metallic implants are placed inside the human body due to the growth in …