EANM/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies
N Aide, C Lasnon, P Veit-Haibach, T Sera… - European journal of …, 2017 - Springer
Quantitative positron emission tomography/computed tomography (PET/CT) can be used as
diagnostic or prognostic tools (ie single measurement) or for therapy monitoring (ie …
diagnostic or prognostic tools (ie single measurement) or for therapy monitoring (ie …
Performance evaluation of the Vereos PET/CT system according to the NEMA NU2-2012 standard
I Rausch, A Ruiz, I Valverde-Pascual… - Journal of Nuclear …, 2019 - Soc Nuclear Med
The aim of this study was to evaluate the physical performance of the Vereos whole-body
PET/CT system according to the National Electrical Manufacturers Association (NEMA) NU2 …
PET/CT system according to the National Electrical Manufacturers Association (NEMA) NU2 …
A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: The QUEST Phantom Study
KP Willowson, M Tapner… - European journal of …, 2015 - Springer
Purpose To investigate and compare the quantitative accuracy of 90 Y imaging across
different generation PET/CT scanners, for the purpose of dosimetry after radioembolization …
different generation PET/CT scanners, for the purpose of dosimetry after radioembolization …
Personalizing medicine through hybrid imaging and medical big data analysis
Medical imaging has evolved from a pure visualization tool to representing a primary source
of analytic approaches toward in vivo disease characterization. Hybrid imaging is an integral …
of analytic approaches toward in vivo disease characterization. Hybrid imaging is an integral …
Performance evaluation of the Biograph mCT Flow PET/CT system according to the NEMA NU2-2012 standard
Background The purpose of the study is to evaluate the physical performance of a Biograph
mCT Flow 64-4R PET/CT system (Siemens Healthcare, Germany) and to compare clinical …
mCT Flow 64-4R PET/CT system (Siemens Healthcare, Germany) and to compare clinical …
Optimized feature extraction for radiomics analysis of 18F-FDG PET imaging
Radiomics analysis of 18F-FDG PET/CT images promises well for an improved in vivo
disease characterization. To date, several studies have reported significant variations in …
disease characterization. To date, several studies have reported significant variations in …
Harmonizing FDG PET quantification while maintaining optimal lesion detection: prospective multicentre validation in 517 oncology patients
Purpose Point-spread function (PSF) or PSF+ time-of-flight (TOF) reconstruction may
improve lesion detection in oncologic PET, but can alter quantitation resulting in variable …
improve lesion detection in oncologic PET, but can alter quantitation resulting in variable …
Monitoring of plexiform neurofibroma in children and adolescents with neurofibromatosis type 1 by [18F]FDG‐PET imaging. Is it of value in asymptomatic patients?
Purpose About 10% of patients with neurofibromatosis type 1 (NF‐1) develop malignant
peripheral nerve sheath tumours (MPNST) mostly arising in plexiform neurofibroma (PN); …
peripheral nerve sheath tumours (MPNST) mostly arising in plexiform neurofibroma (PN); …
Quality control in PET/CT and PET/MRI: Results of a survey amongst European countries
Abstract Purpose An EFOMP Working Group (WG) was created in 2020 to establish
recommendations for PET/CT/MRI Quality Control (QC). The WG's intention was to create a …
recommendations for PET/CT/MRI Quality Control (QC). The WG's intention was to create a …
Radiation dose from whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography: nationwide survey in Korea
HW Kwon, JP Kim, HJ Lee, JC Paeng… - Journal of Korean …, 2016 - synapse.koreamed.org
The purpose of this study was to estimate average radiation exposure from 18F-
fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) …
fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) …