Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
The Sereine test: advances towards short and reproducible measurements of a whole building heat transfer coefficient
S Juricic, M Rabouille, A Challansonnex, A Jay… - Energy and …, 2023 - Elsevier
In a global effort to reduce carbon emissions from the building sector, reliable on-site
thermal intrinsic performance measurements could positively contribute to reducing the …
thermal intrinsic performance measurements could positively contribute to reducing the …
Extending the validity of co-heating tests to warmer and sunnier weather conditions using an equivalent exterior temperature
The energy consumption of buildings is usually different from that predicted at the design
stage. To measure the performance gap between designed and as-built buildings, it is …
stage. To measure the performance gap between designed and as-built buildings, it is …
Assessing the co-heating test as reference for heat loss coefficient estimation: In-depth analysis on an artificial dataset
In order to bridge the building energy performance gap it is necessary to quantitatively and
qualitatively characterize the actual energy demand of buildings and the thermal behaviour …
qualitatively characterize the actual energy demand of buildings and the thermal behaviour …
Co-cooling, simulation-based exploration of a new method to measure the heat transfer coefficient of a building envelope in hot climate and summer period
K Campagna, A Jay, A Pacquaut… - Journal of Building …, 2024 - Taylor & Francis
The discrepancy between designed and as-built building performance can be quantified by
a heat transfer coefficient (HTC) measurement. A reference method for measuring this …
a heat transfer coefficient (HTC) measurement. A reference method for measuring this …
A large scale artificial dataset to evaluate the impact of on-board monitoring set-ups on the Heat Transfer Coefficient assessment
At the current state, the majority of residential buildings are underperforming in terms of
energy. To assess the current state of the building sector and bridge the gap between the …
energy. To assess the current state of the building sector and bridge the gap between the …
Evaluation of a building envelope Heat Transfer Coefficient in use: Bayesian approach to improve the inclusion of solar gains
Accurately measuring the actual building performance would be a significant step toward
performance contracting. Methods under occupancy have operational advantages but come …
performance contracting. Methods under occupancy have operational advantages but come …
[HTML][HTML] Experimental Investigation of Building Mock-ups and Air Source Heat Pumps in Cold Climates
A Jafri, E Villenuve, M Agelin-Chaab… - Energy and Built …, 2025 - Elsevier
Air source heat pumps (ASHPs) are critical in reducing carbon emissions, particularly in
extreme cold climates like Canada. However, less than 10% of residential buildings in …
extreme cold climates like Canada. However, less than 10% of residential buildings in …
How reliable is the co-heating test?
The predicted or designed envelope's energy performance often differs from the in-reality
achieved one and this phenomenon, known as the building fabric performance gap, is …
achieved one and this phenomenon, known as the building fabric performance gap, is …
Bayesian Approach for Heat Transfer Coefficient Reliable Measurement of In-Use Buildings
A PACQUAUT, S Rouchier, S Juricic, A Jay… - Available at SSRN … - papers.ssrn.com
Abstract Assessing the Heat Transfer Coefficient (HTC) of a building's envelope during
occupancy offers operational advantages, as it does not need to be kept vacant for the …
occupancy offers operational advantages, as it does not need to be kept vacant for the …