Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[LLIBRE][B] CMOS: front-end electronics for radiation sensors
A Rivetti - 2018 - books.google.com
CMOS: Front-End Electronics for Radiation Sensors offers a comprehensive introduction to
integrated front-end electronics for radiation detectors, focusing on devices that capture …
integrated front-end electronics for radiation detectors, focusing on devices that capture …
Front-end ASIC for a Liquid Argon TPC
G De Geronimo, A D'Andragora, S Li… - … & Medical Imaging …, 2010 - ieeexplore.ieee.org
We introduce a front-end application specific integrated circuit (ASIC) for a wire based Time-
Projection-Chamber (TPC) operating in liquid Argon (LAr). The LAr TPC will be used for long …
Projection-Chamber (TPC) operating in liquid Argon (LAr). The LAr TPC will be used for long …
A CMOS baseline holder (BLH) for readout ASICs
As a result of a cooperation between Brookhaven National Laboratory and eV Products a
generation of high performance readout ASICs was developed. One of the novel circuit …
generation of high performance readout ASICs was developed. One of the novel circuit …
Front-end electronics for multichannel semiconductor detector systems
P Grybos - 2010 - cds.cern.ch
Front-end electronics for multichannel semiconductor detektor systems Volume 08, EuCARD
Editorial Series on Accelerator Science and Technology The monograph is devoted to many …
Editorial Series on Accelerator Science and Technology The monograph is devoted to many …
Front-end electronics for imaging detectors
Front-end electronics for imaging detectors with large numbers of pixels (105–107) is
reviewed. The noise limits as a function of detector capacitance and power dissipation are …
reviewed. The noise limits as a function of detector capacitance and power dissipation are …
A CMOS fully compensated continuous reset system
As a result of a cooperation between Brookhaven National Laboratory and eV Products a
generation of high performance readout ASICs was developed. One of the novel circuit …
generation of high performance readout ASICs was developed. One of the novel circuit …
Readout ASIC for 3D position-sensitive detectors
G De Geronimo, E Vernon, K Ackley… - 2007 IEEE Nuclear …, 2007 - ieeexplore.ieee.org
We describe an application specific integrated circuit (ASIC) for 3D position-sensitive
detectors. It was optimized for pixelated CZT sensors, and it measures, corresponding to an …
detectors. It was optimized for pixelated CZT sensors, and it measures, corresponding to an …
Analog peak detector and derandomizer for high-rate spectroscopy
G De Geronimo, A Kandasamy… - IEEE Transactions on …, 2002 - ieeexplore.ieee.org
A compact and accurate readout system has been developed for high-rate spectroscopy
with multi-element detectors. The fully self-triggered system multiplexes the signals from 32 …
with multi-element detectors. The fully self-triggered system multiplexes the signals from 32 …
ASIC with multiple energy discrimination for high-rate photon counting applications
An ASIC for high rate photon counting measurements with multiple energy discrimination is
presented. Optimized for pixelated CdZnTe sensors, the ASIC is composed of 64 channels …
presented. Optimized for pixelated CdZnTe sensors, the ASIC is composed of 64 channels …
Design and Characterization of a Low-Noise Front-End Readout ASIC in 0.18- m CMOS Technology for CZT/Si-PIN Detectors
W Gao, S Li, Y Duan, P Huang, Z Li… - … on Nuclear Science, 2018 - ieeexplore.ieee.org
In this paper, we report the recent development of a low-noise front-end readout application-
specified integrated circuit (ASIC) for cadmium–zinc–telluride (CZT) and Si-pin detectors …
specified integrated circuit (ASIC) for cadmium–zinc–telluride (CZT) and Si-pin detectors …