Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves

NM Wright, C Lauryssen - Neurosurgical Focus, 1998 - thejns.org
Object The 847 active members of the American Association of Neurological
Surgeons/Congress of Neurological Surgeons (AANS/CNS) Section on Disorders of the …

Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique

A Abou Madawi, ATH Casey, GA Solanki, G Tuite… - Journal of …, 1997 - thejns.org
✓ Sixty-one patients treated with C1–2 transarticular screw fixation for spinal instability
participated in a detailed clinical and radiological study to determine outcome and clarify …

Posterior C1–C2 fusion with polyaxial screw and rod fixation

J Harms, RP Melcher - Spine, 2001 - journals.lww.com
Study Design. A novel technique of atlantoaxial stabilization using individual fixation of the
C1 lateral mass and the C2 pedicle with minipolyaxial screws and rods is described. In …

Atlantoaxial fixation using plate and screw method: a report of 160 treated patients

A Goel, KI Desai, DP Muzumdar - Neurosurgery, 2002 - journals.lww.com
OBJECTIVE: We review our experience with the use of the plate and screw method of
fixation in the treatment of 160 patients with atlantoaxial instability during a 14-year period at …

The anatomical suitability of the C1–2 complex for transarticular screw fixation

CG Paramore, CA Dickman, VKH Sonntag - Journal of neurosurgery, 1996 - thejns.org
✓ Posterior transarticular screw fixation of the C1–2 complex has become an accepted
method of rigid internal fixation for patients requiring posterior C1–2 fusion. The principal …

C1–C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note

DK Resnick, EC Benzel - Neurosurgery, 2002 - journals.lww.com
OBJECTIVE AND IMPORTANCE: Transarticular screw fixation of the C1–C2 complex
provides immediate rigid fixation of the unstable spine. The technique is not feasible in a …

Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis

CA Dickman, VKH Sonntag - Neurosurgery, 1998 - journals.lww.com
OBJECTIVE: To assess the outcomes associated with C1-C2 transarticular screw fixation.
METHODS: The clinical outcomes of 121 patients treated with posterior C1-C2 transarticular …

Posterior Atlantoaxial Fixation: Biomechanical: In Vitro: Comparison of Six Different Techniques

M Richter, R Schmidt, L Claes, W Puhl, HJ Wilke - Spine, 2002 - journals.lww.com
Study Design. Six different techniques for atlantoaxial fixation were biomechanically
compared in vitro by nondestructive testing. Objective. To evaluate the immediate three …

Biomechanical testing of posterior atlantoaxial fixation techniques

RP Melcher, CM Puttlitz, FS Kleinstueck, JC Lotz… - Spine, 2002 - journals.lww.com
Study Design. An in vitro biomechanical study of C1–C2 posterior fusion techniques was
conducted using a cadaveric model. Objective. To investigate and compare the acute …

C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy

TJ Coyne, MG Fehlings, MC Wallace, M Bernstein… - …, 1995 - journals.lww.com
Abstract POSTERIOR WIRING TECHNIQUES are the most commonly used methods of