Wind generators ferroresonance overvoltage protection methods: A review
Ferroresonance, as a sustained transient phenomenon associated with excessive voltages
and currents, can cause severe consequences if not mitigated properly. In that regard …
and currents, can cause severe consequences if not mitigated properly. In that regard …
Application of superconductors to suppress ferroresonance overvoltage in DFIG-WECS
MI Mosaad, NA Sabiha, A Abu-Siada… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
While much attention was given in the literature to improve the fault ride through (FRT)
capability of a doubly-fed induction generator (DFIG)-based wind energy conversion system …
capability of a doubly-fed induction generator (DFIG)-based wind energy conversion system …
Fault Current Protection in distribution system connected EVCH: A Review
This paper presents various solutions to reduce or prevent short circuit damages in
distribution system connected Electric Vehicle Charging Stations (EVCS). In EVCSs …
distribution system connected Electric Vehicle Charging Stations (EVCS). In EVCSs …
[HTML][HTML] Analytical solution of serial ferroresonance triggered by circuit breaker operation in solidly grounded power grids
B Wang, C Zhang, Y **a, F Zhang - … Journal of Electrical Power & Energy …, 2023 - Elsevier
Ferroresonance can be induced by Circuit Breaker (CB) switching operations in neutral
point solidly grounded power grids with matching parameters. No complete time domain …
point solidly grounded power grids with matching parameters. No complete time domain …
Research on the mechanism and restraining measures of ferroresonance in distribution network based on ATP-EMTP
H Liu, Q Li, Y Sui, L Liu, H Liu - Electric Power Systems Research, 2023 - Elsevier
In order to monitor the three-phase voltage of the busbar to ground, the substation bus is
usually connected to the electromagnetic voltage transformer by YN connection in the …
usually connected to the electromagnetic voltage transformer by YN connection in the …
[HTML][HTML] High-frequency transformer winding model with adequate protection
High local electric field intensity in transformer windings originating from transient signals is
one of the reasons for transformer failures. Due to the integration of renewable energy …
one of the reasons for transformer failures. Due to the integration of renewable energy …
A new method for ferroresonance suppression in an IEEE 33-bus distribution system integrated with multi distributed generation
AM Abdel-Hamed, MM El-Shafhy, EA Badran - Scientific Reports, 2023 - nature.com
Although integrating a distributed generation (DG) into a distribution system (DS) has
several benefits, it may be accompanied by some issues, such as ferroresonance …
several benefits, it may be accompanied by some issues, such as ferroresonance …
Dynamic analysis and suppression strategy research on a novel fractional-order ferroresonance system
Ferroresonance is characterized by overvoltage and irregular operation in power systems,
which can greatly endanger system equipment. Mechanism analysis of the ferroresonance …
which can greatly endanger system equipment. Mechanism analysis of the ferroresonance …
Compound ferroresonance overvoltage and fault current limiter for power system protection
Power systems are subjected to various types of faults as well as ferroresonance
overvoltages. These results in the interruption of the normal operation of the power grid …
overvoltages. These results in the interruption of the normal operation of the power grid …
Innovative Solid-State Ferroresonance-Suppressing Circuit for Voltage Transformer Protection in Wind Generation Systems
Ferroresonance, as an undesirable disturbance, leads to significant overvoltage and
distorted waveforms. This phenomenon can be highly damaging to voltage transformers and …
distorted waveforms. This phenomenon can be highly damaging to voltage transformers and …