[HTML][HTML] Field programmable gate array applications—A scientometric review

J Ruiz-Rosero, G Ramirez-Gonzalez, R Khanna - Computation, 2019 - mdpi.com
Field Programmable Gate Array (FPGA) is a general purpose programmable logic device
that can be configured by a customer after manufacturing to perform from a simple logic gate …

[HTML][HTML] sEMG signal filtering study using synchrosqueezing wavelet transform with differential evolution optimized threshold

C Li, H Deng, S Yin, C Wang, Y Zhu - Results in Engineering, 2023 - Elsevier
Most gesture recognition studies based on surface electromyography (sEMG) signals focus
on filtering, in which the lack of diversity for considered noises can still be the problem. In …

A proportional fusion adaptation algorithm to reduce noise in sEMG signals of the lower limb

H Li, Y Song, Q Chen, Y Li… - Measurement Science and …, 2024 - iopscience.iop.org
To address issues related to unknown noise pollution and the inadequate performance of
single adaptive noise reduction algorithms in measuring lower limb surface …

Design and FPGA implementation of lattice wave digital notch filter with minimal transient duration

A Sharma, T Kumar Rawat, A Agrawal - IET Signal Processing, 2020 - Wiley Online Library
In this study, the design and field‐programmable gate array (FPGA) implementation of the
digital notch filter with the lattice wave digital filter (LWDF) structure is presented. For …

A review on different filter design techniques and topologies for bio-potential signal acquisition systems

AK Sahu, AK Sahu - 2018 3rd International Conference on …, 2018 - ieeexplore.ieee.org
There are few bio-potentials signals which is used for human-machine interface (HMI). Most
extensively used bio-potential signal for HMI are electroencephalogram (EEG) and …

Design and Simulation of a Tunable 14-Bit IIR Digital Low-Pass Filter Based on FPGA

A Roshanpanah, H Borhanifar - 2022 International Conference …, 2022 - ieeexplore.ieee.org
A 5 th-order tunable IIR digital low-pass filter is presented which can operate from 20 to 70
MHz at a 176-MHz sampling frequency. The number of input and output bits is 14 and 15 …

Filter design based on a novel non-iterative least square method with adjustable parameter

J Chen, Y Yin - 2018 IEEE International Conference on Signal …, 2018 - ieeexplore.ieee.org
Filters designed by a non-iterative least square method traditionally have less stop-band
attenuation and the non-iterative least square method has the shortcoming of being …

Novel non-iterative least square method with adjustable weighting vector for filter design

J Chen, Y Yin - IOP Conference Series: Materials Science and …, 2018 - iopscience.iop.org
A novel non-iterative weighted least square method is presented. The new method
advances the traditional non-iterative least square formula into a new non-iterative weighted …

The Application of Surface Electromyogram Signal in Design of Artificial Limb: A Review

Keerti, K Veer - Applications of Advanced Computing in Systems …, 2021 - Springer
In this paper, one gave the review about the surface electromyography, its feature extraction,
wavelet transform and signal filtering, etc. Surface electromyogram (SEMG) signal has a …

Wiener Filtering for Myoelectric Signal

F González-Espinoza - 2018 - rei.iteso.mx
EMG (Electromyography) signals are used to diagnose muscular pathologies and are also
employed as inputs for electronic applications. However, a major disadvantage in detecting …