Review of non-invasive glucose sensing techniques: optical, electrical and breath acetone
Annual deaths in the US attributed to diabetes are expected to increase from 280,210 in
2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has …
2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has …
A noninvasive accurate measurement of blood glucose levels with Raman spectroscopy of blood in microvessels
N Li, H Zang, H Sun, X Jiao, K Wang, TCY Liu, Y Meng - Molecules, 2019 - mdpi.com
Raman spectra of human skin obtained by laser excitation have been used to non-invasively
detect blood glucose. In previous reports, however, Raman spectra thus obtained were …
detect blood glucose. In previous reports, however, Raman spectra thus obtained were …
Dual-modulation, dual-wavelength, optical polarimetry system for glucose monitoring
A dual modulation optical polarimetry system utilizing both laser intensity and polarization
modulation was designed, built, and tested. The system was designed to reduce complexity …
modulation was designed, built, and tested. The system was designed to reduce complexity …
Three-dimensional correlation method for non-invasive blood glucose monitoring with optical coherence tomography
Y Su, K Cai, J Sun, P Hao, Y Zhang, Y Dong… - Optics and Lasers in …, 2025 - Elsevier
Optical non-invasive glucose monitoring (NIGM) is attractive to diabetes patients and
medical professionals due to its advantages of painlessness, real-time monitoring, less …
medical professionals due to its advantages of painlessness, real-time monitoring, less …
Glucose sensing in oral mucosa simulating phantom using differential absorption based frequency domain low-coherence interferometry
The superluminescent diode based differential absorption frequency domain low-coherence
interferometry (FD-DALCI) technique is proposed and demonstrated for sensing …
interferometry (FD-DALCI) technique is proposed and demonstrated for sensing …
A robust model of an OCT signal in a spectral domain
A Abdurashitov, V Tuchin - Laser Physics Letters, 2018 - iopscience.iop.org
Optical coherence tomography (OCT) relies on ballistic back scattered photons to construct
depth resolved optical slices of a specimen. However, the theory of OCT is generally math …
depth resolved optical slices of a specimen. However, the theory of OCT is generally math …
Quantification of cell-free layer thickness and cell distribution of blood by optical coherence tomography
A high-speed optical coherence tomography (OCT) with 1-μ m axial resolution was applied
to assess the thickness of a cell-free layer (CFL) and a spatial distribution of red blood cells …
to assess the thickness of a cell-free layer (CFL) and a spatial distribution of red blood cells …
Sensitivity improvement of one-shot Fourier spectroscopic imager for realization of noninvasive blood glucose sensors in smartphones
N Kawashima, K Nogo, S Hosono… - Optical …, 2016 - spiedigitallibrary.org
The use of the wide-field-stop and beam-expansion method for sensitivity enhancement of
one-shot Fourier spectroscopy is proposed to realize health care sensors installed in …
one-shot Fourier spectroscopy is proposed to realize health care sensors installed in …
Spectral Domain Optical Coherence Tomography (SD-OCT) for Salt Quantification in Blood.
The measurement of salt levels in blood assume an essential part in the control of numerous
real capacities and is contained in body liquids that vehicle oxygen and supplements. We …
real capacities and is contained in body liquids that vehicle oxygen and supplements. We …
Diagnosis of Ocular Diseases Using Optical Coherence Tomography (OCT) at λ= 840 nm.
Optical coherence tomography (OCT) is an imaging technique performed without any
incision in the body and has a significant importance in biomedical diagnostics. OCT has …
incision in the body and has a significant importance in biomedical diagnostics. OCT has …