Experimental evaluation of energy dissipation and viscous dam** of repaired and strengthened RC columns with CFRP jacketing under biaxial load

H Rodrigues, A Furtado, A Arêde - Engineering Structures, 2017 - Elsevier
The seismic repair and retrofitting of reinforced concrete (RC) columns have been the focus
of innumerous studies and from the literature it can be concluded that the biaxial horizontal …

[PDF][PDF] Retrofitting of concrete structure with fiber reinforced polymer

A Dasgupta - International Journal, 2018 - academia.edu
Retrofitting is the modification of existing structures to improve the performance and
durability of the structure. Day to day concrete structure to need retrofitting due to various …

[PDF][PDF] Retrofitting and strengthening of damaged reinforced concrete columns using steel angels wrapped with steel wire mesh

MK Abd-ELhamed, HA Ezz-Eldeen - International Journal of Modern …, 2014 - academia.edu
Six reinforced concrete rectangular columns with a cross section 120x160 mm and 800 mm
length were casted and tested until failure. Two control columns were tested under axial …

Numerical modelling of RC strengthened columns under biaxial loading

H Rodrigues, A Furtado, A Arêde, H Varum - Innovative Infrastructure …, 2016 - Springer
During an earthquake, the reinforced concrete (RC) structures are subjected to deformations
that may lead their structural elements to exceed the corresponding resistance limit state …

Need for structural health assessment of RCC buildings

MB De Souza, PP Savoikar - IOP Conference Series: Earth and …, 2023 - iopscience.iop.org
As civil engineering structures get older, there is a need to maintain, repair, retrofit and
restore the structures once structural health of the structure is checked and found that it is …

[PDF][PDF] Yetersiz Betonarme Kolonlar için Lifli Polimer Güçlendirme Tasarım Kurallarının İrdelenmesi

O Özcan, B Binici, G Özcebe - Teknik Dergi, 2010 - dergipark.org.tr
Yetersiz betonarme kolonların potansiyel plastik mafsal bölgelerinde lifli polimer (LP)
sargılama ile deformasyon kapasitelerinin artırılması son yıllarda oldukça popüler hale …

[PDF][PDF] Penggunaan Carbon Fiber-Reinforced Polymer Sebagai Perkuatan Kolom Beton Bertulang Akibat Beban Siklik Untuk Meningkatkan Daktilitas Perpindahan …

K Achmad, A Soehardjono, T Tavio - Teknol. dan Kejuru., 2012 - academia.edu
Penelitian ini bertujuan untuk meningkatkan daktilitas perpindahan pada spesimen kolom
yang diberi perkuatan CFRP (Carbon Fiber Reinforced Polymer). Ada dua spesimen kolom …

Investigation of FRP strengthening design rules for insufficient RC columns

O Özcan, B Binici, G Özcebe - Teknik Dergi, 2010 - dergipark.org.tr
Increasing the deformation capacities of code-incompliant RC columns by wrap** their
potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather …