Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Closed-form expressions for the estimation of the minimum backflashover current of overhead transmission lines
The minimum backflashover current, I BF, of typical overhead transmission lines is estimated
through ATP-EMTP simulations considering the tower ground resistance and AC voltage …
through ATP-EMTP simulations considering the tower ground resistance and AC voltage …
Estimation of the minimum shielding failure flashover current for first and subsequent lightning strokes to overhead transmission lines
ATP-EMTP simulations are performed to estimate the minimum shielding failure current
causing flashover in overhead transmission lines with operating voltage in the range of 66 …
causing flashover in overhead transmission lines with operating voltage in the range of 66 …
Modelling of 132 kV overhead transmission lines by using ATP/EMTP for shielding failure pattern recognition
N Zawani, M Faizuhar - procedia Engineering, 2013 - Elsevier
Lightning overvoltage is the major cause of the transmission line interruption in Malaysia. It
is the main reason that endangers the safety and reliability of transmission line system. The …
is the main reason that endangers the safety and reliability of transmission line system. The …
Synchrophasor sensor networks for grid communication and protection
H Gharavi, B Hu - Proceedings of the IEEE, 2017 - ieeexplore.ieee.org
This paper focuses primarily on leveraging synchronized current/voltage amplitudes and
phase angle measurements to foster new categories of applications, such as improving the …
phase angle measurements to foster new categories of applications, such as improving the …
ATP-EMTP modeling and performance test of different type lightning arrester on 132kv overhead transmission tower
MZ Islam, MR Rashed… - 2017 3rd International …, 2017 - ieeexplore.ieee.org
Lightning and switching surges are the main causes of over voltages in power system. If any
high voltage transmission tower stroked by lightning the insulation of the line and equipment …
high voltage transmission tower stroked by lightning the insulation of the line and equipment …
Investigation of lightning overvoltage on 220 kv transmission lines in bhutan using ATP-EMTP
This paper provides an examination of the impact of lightning strikes on a 220 kV double
circuit (D/C) high voltage transmission line in Bhutan. The study employs the ATP-EMTP …
circuit (D/C) high voltage transmission line in Bhutan. The study employs the ATP-EMTP …
Study on Lightning Surge of Overhead Line-GIL Hybrid Line
Z Ma, X Huo, P Chu, C Jia - 2023 4th International Conference …, 2023 - ieeexplore.ieee.org
Gas-insulated transmission line (GIL) has a high risk of lightning overvoltage as it is usually
connected to exposed overhead line. The transient models of hybrid transmission system …
connected to exposed overhead line. The transient models of hybrid transmission system …
[PDF][PDF] Analysis of lightning strike with corona on OHTL near the substation by EMTP
Lightning protection and insulation coordination of transmission lines and substations
require an accurate knowledge of the magnitudes and waveforms of lightning overvoltage …
require an accurate knowledge of the magnitudes and waveforms of lightning overvoltage …
[PDF][PDF] Characteristics and behaviour of transient current during lightning strikes on transmission tower
P Lertwanitrot, P Kettranan… - Proceedings of the …, 2015 - researchgate.net
This paper investigates on the characteristics of current when lightning strikes on the
conductor of transmission lines. The impedance of multistory model based on the 115 kV …
conductor of transmission lines. The impedance of multistory model based on the 115 kV …
[PDF][PDF] ATP-EMTP Modeling of Distance Relays to Simulate Single Line to Ground Fault Performance in Transmission Network
AR Hakim - Master of science thesis, TU Delft University of …, 2015 - repository.tudelft.nl
The thesis deals with the modeling and simulation of distance relays in ATP-EMTP.
Transmission line which is 125.6 miles long operates at 60 Hz and 115 kV line voltages are …
Transmission line which is 125.6 miles long operates at 60 Hz and 115 kV line voltages are …