Increasing frame rate of echocardiography based on a novel 2d spatio-temporal meshless interpolation
Background: Increasing temporal resolution through numerical methods aids clinicians to
evaluate fast moving structures of the heart with more confidence. Methodology: In this …
evaluate fast moving structures of the heart with more confidence. Methodology: In this …
High frame rate ultrasound imaging by means of tensor completion: Application to echocardiography
High frame rate ultrasound (US) imaging enables the monitoring of fast-moving organs. In
echocardiography, this is especially needed due to the existence of rapidly moving …
echocardiography, this is especially needed due to the existence of rapidly moving …
Temporal super-resolution of echocardiography using a novel high-precision non-polynomial interpolation
Higher frame rates are very useful for improving medical diagnosis in fast-moving parts of
the heart, especially in the valves. To this end, we propose a non-polynomial interpolation …
the heart, especially in the valves. To this end, we propose a non-polynomial interpolation …
Increasing the frame rate of echocardiography images based on a novel interpolation technique
High-temporal cardiac imaging allows for more accurate diagnostics for heart diseases. The
objective of the present work is to propose a technique to improve the temporal resolution of …
objective of the present work is to propose a technique to improve the temporal resolution of …
Temporal super-resolution of 2D/3D echocardiography using cubic B-spline interpolation
Echocardiography is an important imaging modality in daily clinical practices. Lack of image
quality and limited number of frames per second are the major problems of this modality …
quality and limited number of frames per second are the major problems of this modality …
2d/3d echocardiography frame rate enhancement by means of a novel spatio-temporal reconstruction technique
Frame rate, ie, the number of frames displayed per second, is a crucial aspect in ultrasound
imaging. Increasing the frame rate is required in echocardiography because it helps …
imaging. Increasing the frame rate is required in echocardiography because it helps …
A fast and high frame rate adaptive beamforming using DCT‐based RF‐line recovery in line‐by‐line ultrasound imaging
Ultrasound imaging is an important modality used in medical imaging. One of the significant
stages in the ultrasound imaging is the beamforming process. This article proposes a new …
stages in the ultrasound imaging is the beamforming process. This article proposes a new …
[HTML][HTML] Frame rate up-conversion in cardiac ultrasound
HN Mirarkolaei, SR Snare, AHS Solberg… - … Signal Processing and …, 2020 - Elsevier
The temporal resolution of echocardiographic sequences affects the interpretation of cardiac
motion as well as the viewing experience. Temporal resolution, however, is limited by the …
motion as well as the viewing experience. Temporal resolution, however, is limited by the …
Self-organized maps and high-frequency image detail for mri image enhancement
K Ahmadian, HR Reza-Alikhani - IEEE Access, 2021 - ieeexplore.ieee.org
Magnetic resonance imaging (MRI) is a medical technology that uses powerful magnets,
radio waves, and a computer to produce images of the body's internal organs. The patient …
radio waves, and a computer to produce images of the body's internal organs. The patient …
A robust bidirectional motion-compensated interpolation algorithm to enhance temporal resolution of 3D echocardiography
HN Mirarkolaei, SR Snare, AHS Solberg - Biomedical Signal Processing …, 2021 - Elsevier
High frame rate three-dimensional echocardiography (3DE) improves the assessment of the
cardiac dynamics by providing a realistic view of the cardiac structures. However, since the …