Low‐field MRI: An MR physics perspective
Historically, clinical MRI started with main magnetic field strengths in the∼ 0.05–0.35 T
range. In the past 40 years there have been considerable developments in MRI hardware …
range. In the past 40 years there have been considerable developments in MRI hardware …
Accessible magnetic resonance imaging: A review
The role of MRI in diagnostics, prognostics, and discoveries in basic sciences has been well
established. However, access to this life‐saving technology is largely restricted to countries …
established. However, access to this life‐saving technology is largely restricted to countries …
[HTML][HTML] On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
The spatial resolution of magnetoencephalography (MEG) can be increased from that of
conventional SQUID-based systems by employing on-scalp sensor arrays of eg optically …
conventional SQUID-based systems by employing on-scalp sensor arrays of eg optically …
Low-cost high-performance MRI
Abstract Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize
anatomical structure and function non-invasively with high spatial and temporal resolution …
anatomical structure and function non-invasively with high spatial and temporal resolution …
Instrumentation for hydrogenative parahydrogen-based hyperpolarization techniques
The unique properties of the entangled, antisymmetric nuclear spin state of dihydrogen,
parahydrogen (pH2), has intrigued physicists, chemists, and other scientists for almost a …
parahydrogen (pH2), has intrigued physicists, chemists, and other scientists for almost a …
Sub-pT magnetic field detection by tunnel magneto-resistive sensors
We developed tunnel magneto-resistive (TMR) sensors based on magnetic tunnel junctions
(MTJs) that are able to detect a weak, sub-pT, magnetic field at a low frequency. Small …
(MTJs) that are able to detect a weak, sub-pT, magnetic field at a low frequency. Small …
[HTML][HTML] IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Magnetoencephalography (MEG) records weak magnetic fields outside the human head
and thereby provides millisecond-accurate information about neuronal currents supporting …
and thereby provides millisecond-accurate information about neuronal currents supporting …
New insights for biosensing: Lessons from microbial defense systems
Microorganisms have gained defense systems during the lengthy process of evolution over
millions of years. Such defense systems can protect them from being attacked by invading …
millions of years. Such defense systems can protect them from being attacked by invading …
SQUIDs in biomagnetism: a roadmap towards improved healthcare
R Körber, JH Storm, H Seton, JP Mäkelä… - Superconductor …, 2016 - iopscience.iop.org
Globally, the demand for improved health care delivery while managing escalating costs is a
major challenge. Measuring the biomagnetic fields that emanate from the human brain …
major challenge. Measuring the biomagnetic fields that emanate from the human brain …
[책][B] Brain signals: physics and mathematics of MEG and EEG
RJ Ilmoniemi, J Sarvas - 2019 - books.google.com
A unified treatment of the generation and analysis of brain-generated electromagnetic fields.
In Brain Signals, Risto Ilmoniemi and Jukka Sarvas present the basic physical and …
In Brain Signals, Risto Ilmoniemi and Jukka Sarvas present the basic physical and …