Nuclear physics in particle therapy: a review

M Durante, H Paganetti - Reports on Progress in Physics, 2016 - iopscience.iop.org
Charged particle therapy has been largely driven and influenced by nuclear physics. The
increase in energy deposition density along the ion path in the body allows reducing the …

Range uncertainties in proton therapy and the role of Monte Carlo simulations

H Paganetti - Physics in Medicine & Biology, 2012 - iopscience.iop.org
The main advantages of proton therapy are the reduced total energy deposited in the patient
as compared to photon techniques and the finite range of the proton beam. The latter adds …

In vivo proton range verification: a review

AC Knopf, A Lomax - Physics in Medicine & Biology, 2013 - iopscience.iop.org
Protons are an interesting modality for radiotherapy because of their well defined range and
favourable depth dose characteristics. On the other hand, these same characteristics lead to …

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

M Testa, J Schümann, HM Lu, J Shin… - Medical …, 2013 - Wiley Online Library
Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently
developed with the specific aim of making Monte Carlo simulations user‐friendly for …

A comprehensive theoretical comparison of proton imaging set-ups in terms of spatial resolution

N Krah, F Khellaf, JM Létang, S Rit… - Physics in Medicine & …, 2018 - iopscience.iop.org
We present a comprehensive analytical comparison of four types of proton imaging set-ups
and, to this end, develop a mathematical framework to calculate the width of the uncertainty …

Proton radiography and proton computed tomography based on time-resolved dose measurements

M Testa, JM Verburg, M Rose, CH Min… - Physics in Medicine …, 2013 - iopscience.iop.org
We present a proof of principle study of proton radiography and proton computed
tomography (pCT) based on time-resolved dose measurements. We used a prototype, two …

The reliability of proton-nuclear interaction cross-section data to predict proton-induced PET images in proton therapy

S Espana, X Zhu, J Daartz, G El Fakhri… - Physics in Medicine …, 2011 - iopscience.iop.org
In vivo PET range verification relies on the comparison of measured and simulated activity
distributions. The accuracy of the simulated distribution depends on the accuracy of the …

Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs)

C Liu, Z Li, W Hu, L **ng, H Peng - Physics in Medicine & Biology, 2019 - iopscience.iop.org
Online proton range/dose verification based on measurements of proton-induced positron
emitters is a promising strategy for quality assurance in proton therapy. Because of the …

Simulation studies of time reversal‐based protoacoustic reconstruction for range and dose verification in proton therapy

Y Yu, Z Li, D Zhang, L **ng, H Peng - Medical physics, 2019 - Wiley Online Library
Purpose In vivo range verification in proton therapy is a critical step to help minimize range
and dose uncertainty. We propose to employ a time reversal (TR)‐based approach using …

Proton range verification using a range probe: definition of concept and initial analysis

M Mumot, C Algranati, M Hartmann… - Physics in Medicine …, 2010 - iopscience.iop.org
Proton therapy can be particularly sensitive to changes or errors in range. Thus, methods for
the in vivo measurement of range could be of great use to improve the quality and accuracy …