Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Optimizing stainless steel tensile strength analysis: through data exploration and machine learning design with Streamlit
Abstract The use of Exploratory Data Analysis (EDA) and machine learning in material
science has rapidly advanced in recent years. EDA enables researchers to thoroughly …
science has rapidly advanced in recent years. EDA enables researchers to thoroughly …
[HTML][HTML] Elastic properties of as-solidified Ti-Zr binary alloys for biomedical applications
T Shiraishi, K Yubuta, T Shishido… - Materials …, 2016 - jstage.jst.go.jp
Abstract Young's modulus (E), shear modulus (G), bulk modulus (K) and Poisson's ratio (ν)
of Ti-Zr binary alloys containing 20, 40, 50, 60, 70 and 80 at% Zr and component pure …
of Ti-Zr binary alloys containing 20, 40, 50, 60, 70 and 80 at% Zr and component pure …
Nanostructuring of additively manufactured 316L stainless steel using high-pressure torsion technique: an X-ray line profile analysis study
Experiments were conducted to reveal the nanostructure evolution in additively
manufactured (AMed) 316L stainless steel due to severe plastic deformation (SPD). SPD …
manufactured (AMed) 316L stainless steel due to severe plastic deformation (SPD). SPD …
Microstructural characterization, defect and hardness of titanium femoral knee joint produced using vertical centrifugal investment casting
Centrifugal investment casting is an attractive method of producing orthopedic implants. This
study investigated the effects of low rotational speed of vertical centrifugal investment …
study investigated the effects of low rotational speed of vertical centrifugal investment …
Evaluation of Ti-6Al-7Nb femoral stem fabricated by centrifugal investment casting using fatigue test
Ti-6Al-7Nb is widely used for medical implant application due to its excellent
biocompatibility, good corrosion resistance and low density. Another essential feature that …
biocompatibility, good corrosion resistance and low density. Another essential feature that …
Primary stability recognition of the newly designed cementless femoral stem using digital signal processing
Stress shielding and micromotion are two major issues which determine the success of
newly designed cementless femoral stems. The correlation of experimental validation with …
newly designed cementless femoral stems. The correlation of experimental validation with …
Artificial organs 2014: a year in review
PS Malchesky - Artificial Organs, 2015 - Wiley Online Library
Abstract In this Editor's Review, articles published in 2014 are organized by category and
briefly summarized. We aim to provide a brief reflection of the currently available worldwide …
briefly summarized. We aim to provide a brief reflection of the currently available worldwide …
Fatigue design space for porous titanium alloy femoral stems: computational approach
The objective of this study is to develop a design space for selecting porous titanium alloy
femoral stems with different stiffnesses for fatigue applications. Finite element models of …
femoral stems with different stiffnesses for fatigue applications. Finite element models of …
Taguchi approach for modelling of surface hardness in investment casting
This paper deals with modelling of surface hardness in investment casting as a case study of
ball valve spherical disc. Three controllable factors of the investment casting process …
ball valve spherical disc. Three controllable factors of the investment casting process …
[PDF][PDF] Fabrication of low-cost hip implant using direct metal laser sintering technique
Total hip replacement (THR) is the most popular surgery been performed in orthopedic
surgery due to the inclination of musculoskeletal disorder and the aging population …
surgery due to the inclination of musculoskeletal disorder and the aging population …