Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Design, implementation, and medical applications of 2-D ultrasound sparse arrays
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture.
Such an array is typically characterized by a limited number of elements, which in most …
Such an array is typically characterized by a limited number of elements, which in most …
Anatomic and functional imaging using row–column arrays
JA Jensen, M Schou, LT Jørgensen… - IEEE transactions on …, 2022 - ieeexplore.ieee.org
Row–column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a
greatly reduced number of elements compared to fully populated arrays. They, however …
greatly reduced number of elements compared to fully populated arrays. They, however …
Ultrasound open platforms for next-generation imaging technique development
Open platform (OP) ultrasound systems are aimed primarily at the research community. They
have been at the forefront of the development of synthetic aperture, plane wave, shear wave …
have been at the forefront of the development of synthetic aperture, plane wave, shear wave …
3-D super-resolution ultrasound imaging with a 2-D sparse array
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution
processing method can visualize 3-D microvascular structures by overcoming the diffraction …
processing method can visualize 3-D microvascular structures by overcoming the diffraction …
ULA-OP 256: A 256-channel open scanner for development and real-time implementation of new ultrasound methods
Open scanners offer an increasing support to the ultrasound researchers who are involved
in the experimental test of novel methods. Each system presents specific performance in …
in the experimental test of novel methods. Each system presents specific performance in …
Density-tapered spiral arrays for ultrasound 3-D imaging
The current high interest in 3-D ultrasound imaging is pushing the development of 2-D
probes with a challenging number of active elements. The most popular approach to limit …
probes with a challenging number of active elements. The most popular approach to limit …
Experimental 3-D ultrasound imaging with 2-D sparse arrays using focused and diverging waves
Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are
increasingly investigated. However, the experimental test of new 3-D US approaches is …
increasingly investigated. However, the experimental test of new 3-D US approaches is …
Sparse convolutional beamforming for ultrasound imaging
The standard technique used by commercial medical ultrasound systems to form B-mode
images is delay and sum (DAS) beamforming. However, DAS often results in limited image …
images is delay and sum (DAS) beamforming. However, DAS often results in limited image …
2-D ultrasound sparse arrays multidepth radiation optimization using simulated annealing and spiral-array inspired energy functions
Full matrix arrays are excellent tools for 3-D ultrasound imaging, but the required number of
active elements is too high to be individually controlled by an equal number of scanner …
active elements is too high to be individually controlled by an equal number of scanner …
Next generation NDE sensor systems as IIoT elements of industry 4.0
ABSTRACT Industry 4.0 (I4. 0) describes the current revolution of the industrial world with a
strong impact on the complete production sector. Data about production processes and the …
strong impact on the complete production sector. Data about production processes and the …