Full‐scale shaking table test and numerical analysis of structural frames with SMA cable‐restrained base isolation
Restrainer is a promising solution for deformation control of isolated systems. The present
study comprehensively discusses the behavior, design and potential application of a novel …
study comprehensively discusses the behavior, design and potential application of a novel …
Phenomenological modeling of fiber‐reinforced elastomeric isolators at multiple lateral deformation levels
Unbonded fiber‐reinforced elastomeric isolators (FREIs) are a cost‐effective seismic
isolation technology that uses lightweight fiber‐fabric reinforcement and forgoes the …
isolation technology that uses lightweight fiber‐fabric reinforcement and forgoes the …
Comparative study on the effectiveness of fluid viscous dampers and base isolation: an approach toward enhancing seismic performance of composite structures
R Thakur, AK Tiwary - Innovative Infrastructure Solutions, 2023 - Springer
This research paper presents an in-depth investigation into the seismic response of hybrid
structures integrated with fluid viscous dampers (FVDs) and base isolation. Severe seismic …
structures integrated with fluid viscous dampers (FVDs) and base isolation. Severe seismic …
Comprehensive evaluation of seismic fragility in base isolated buildings enhanced with supplemental dampers considering pounding phenomenon
Base isolation is a proven technology effective in minimizing earthquake-induced damage to
both the structural and non-structural elements (especially freestanding contents) of …
both the structural and non-structural elements (especially freestanding contents) of …
Maximum response prediction of base-isolated structure with a slip-type damper system preventing excessive displacement
J Kim, S Kuwahara, TS Kim, HY Park - Structures, 2024 - Elsevier
Securing the stability of seismic isolation structures under extreme loads is one of the
challenges for countries located in earthquake-prone areas. In Japan, large-scale …
challenges for countries located in earthquake-prone areas. In Japan, large-scale …
Enhancing the overturning resistance capacity of high aspect ratio structure through hybrid base isolation and inter-storey isolation
J Zhang, Y Li, H Yang, X Ji, L Gu, W Li, B Wang… - Soil Dynamics and …, 2024 - Elsevier
The high-aspect ratio of structures is usually limited to a small range for base isolation (BI),
due to the necessity of ensuring resistance to overturning. This limitation restricts the …
due to the necessity of ensuring resistance to overturning. This limitation restricts the …
Influence of modeling choices on seismic response of a steel reticulated dome
AA Somkuwar, R Matsui, T Okazaki - Journal of Constructional Steel …, 2025 - Elsevier
The choice of element formulation concerning distributed plasticity and dam** models for
inelastic systems has not been extensively studied in the context of spatial structures. The …
inelastic systems has not been extensively studied in the context of spatial structures. The …
Gravity framing and composite action effects on residual drifts of steel SMFs
In this study, the effects of gravity framing and composite action on the residual drift
performance of steel special moment frames (SMFs) are investigated. Four steel structures …
performance of steel special moment frames (SMFs) are investigated. Four steel structures …
A codifiable methodology for estimating pallet sliding displacements on steel racking systems
To facilitate the logistic processes within a modern warehouse, the contents of steel racking
systems are not mechanically connected to the supporting beams, allowing a content …
systems are not mechanically connected to the supporting beams, allowing a content …
Frequency-independent dam** models for a high-rise building with simultaneous horizontal and vertical seismic motions
Recent seismic analyses indicate that the structural dam** ratio should be considered
frequency-independent, for safe and accurate estimations. In response, dam** models …