Retinal imaging and image analysis

MD Abràmoff, MK Garvin… - IEEE reviews in biomedical …, 2010 - ieeexplore.ieee.org
Many important eye diseases as well as systemic diseases manifest themselves in the
retina. While a number of other anatomical structures contribute to the process of vision, this …

Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns

MF Kraus, B Potsaid, MA Mayer, R Bock… - Biomedical optics …, 2012 - opg.optica.org
High speed Optical Coherence Tomography (OCT) has made it possible to rapidly capture
densely sampled 3D volume data. One key application is the acquisition of high quality in …

Ultrahigh speed spectral/Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second

B Potsaid, I Gorczynska, VJ Srinivasan, Y Chen… - Optics express, 2008 - opg.optica.org
We demonstrate ultrahigh speed spectral/Fourier domain optical coherence tomography
(OCT) using an ultrahigh speed CMOS line scan camera at rates of 70,000-312,500 axial …

Multi-mhz retinal oct

T Klein, W Wieser, L Reznicek, A Neubauer… - Biomedical optics …, 2013 - opg.optica.org
We analyze the benefits and problems of in vivo optical coherence tomography (OCT)
imaging of the human retina at A-scan rates in excess of 1 MHz, using a 1050 nm Fourier …

Involuntary eye motion correction in retinal optical coherence tomography: Hardware or software solution?

A Baghaie, Z Yu, RM D'Souza - Medical image analysis, 2017 - Elsevier
In this paper, we review state-of-the-art techniques to correct eye motion artifacts in Optical
Coherence Tomography (OCT) imaging. The methods for eye motion artifact reduction can …

Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization

MF Kraus, JJ Liu, J Schottenhamml, CL Chen… - Biomedical optics …, 2014 - opg.optica.org
Variability in illumination, signal quality, tilt and the amount of motion pose challenges for
post-processing based 3D-OCT motion correction algorithms. We present an advanced 3D …

Automated non-rigid registration and mosaicing for robust imaging of distinct retinal capillary beds using speckle variance optical coherence tomography

HC Hendargo, R Estrada, SJ Chiu, C Tomasi… - Biomedical optics …, 2013 - opg.optica.org
Variance processing methods in Fourier domain optical coherence tomography (FD-OCT)
have enabled depth-resolved visualization of the capillary beds in the retina due to the …

Automated motion correction using parallel-strip registration for wide-field en face OCT angiogram

P Zang, G Liu, M Zhang, C Dongye, J Wang… - Biomedical optics …, 2016 - opg.optica.org
We propose an innovative registration method to correct motion artifacts for wide-field optical
coherence tomography angiography (OCTA) acquired by ultrahigh-speed swept-source …

Method and apparatus for motion correction and image enhancement for optical coherence tomography

MFG Kraus, BM Potsaid, JG Fujimoto… - US Patent …, 2016 - Google Patents
2011-08-16 Assigned to MASSACHUSETTS INSTITUTE OF TECHNOLOGY reassignment
MASSACHUSETTS INSTITUTE OF TECHNOLOGY ASSIGNMENT OF ASSIGNORS …

Correcting motion artifacts in retinal spectral domain optical coherence tomography via image registration

S Ricco, M Chen, H Ishikawa, G Wollstein… - … Image Computing and …, 2009 - Springer
Spectral domain optical coherence tomography (SD-OCT) is an important tool for the
diagnosis of various retinal diseases. The measurements available from SD-OCT volumes …