Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Efficient Reverse Converters for 4-Moduli Sets {2 , 2 , 2 , 2 } and {2 , 2 , 2 , 2 } Based on CRTs Algorithm.
Speed and complexity of a reverse converter are two important factors that affect the
performance of a residue number system. In this paper, two efficient reverse converters are …
performance of a residue number system. In this paper, two efficient reverse converters are …
High Speed Residue to Binary Converter for the New Four-Moduli Set {22n , 2 n + 1, 2 n/2 + 1, 2 n/2−1}
MR Noorimehr, M Hosseinzadeh, R Farshidi - Arabian Journal for Science …, 2014 - Springer
The performance of a residue number system (RNS) depends on speed of internal RNS
arithmetic unit as well as speed and complexity of residue to binary converter. In this paper …
arithmetic unit as well as speed and complexity of residue to binary converter. In this paper …
A parallel architecture for efficient reverse converter using Chinese remainder theorem
VP Sahare, SV Rathkanthiwar - 2015 International Conference …, 2015 - ieeexplore.ieee.org
In this paper, we introduced a two level architecture for designing a residue to binary
number system converter with a four moduli set that will use Chinese remainder theorem …
number system converter with a four moduli set that will use Chinese remainder theorem …
Efficient Reverse Converters for 4-Moduli Sets {2^ sup 2n-1^-1, 2^ sup n^, 2^ sup n^+ 1, 2^ sup n^-1} and {2^ sup 2n-1^, 2^ sup 2n-1^-1, 2^ sup n^+ 1, 2^ sup n^-1} …
MR Noorimehr, M Hosseinzadeh… - Circuits, Systems, and …, 2014 - search.proquest.com
Efficient Reverse Converters for 4-Moduli Sets {22n−1 − 1, 2 n, 2n + 1, 2 n − 1} and {2 , 22n−1
− 1, 2n + 1, 2 n − 1 Page 1 Circuits Syst Signal Process (2014) 33:3145–3163 DOI 10.1007/s00034-014-9798-1 …
− 1, 2n + 1, 2 n − 1 Page 1 Circuits Syst Signal Process (2014) 33:3145–3163 DOI 10.1007/s00034-014-9798-1 …
Efficient Reverse Converters for 4-Moduli Sets {2, 2, 2, 2} and {2, 2, 2, 2} Based on CRTs Algorithm
Speed and complexity of a reverse converter are two important factors that affect the
performance of a residue number system. In this paper, two efficient reverse converters are …
performance of a residue number system. In this paper, two efficient reverse converters are …
High Speed Residue to Binary Converter for the New Four-Moduli Set {2, 2+ 1, 2+ 1, 2− 1}.
The performance of a residue number system (RNS) depends on speed of internal RNS
arithmetic unit as well as speed and complexity of residue to binary converter. In this paper …
arithmetic unit as well as speed and complexity of residue to binary converter. In this paper …