Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Harmonic source detection methods: A systematic literature review
Ensuring the quality of power supply is a main target of the power utility companies
worldwide. Harmonic distortion is one of the power quality problems that can result either …
worldwide. Harmonic distortion is one of the power quality problems that can result either …
On the dominant harmonic source identification—Part I: Review of methods
Analyzing the harmonic distortions at the point of common coupling is thoroughly addressed
in this two-part paper. The main aim of such an analysis is to identify which of the utility and …
in this two-part paper. The main aim of such an analysis is to identify which of the utility and …
Power system harmonics research: a survey
GK Singh - European Transactions on Electrical Power, 2009 - Wiley Online Library
The increased use of power electronic controlled equipment, such as variable speed drives,
automated production lines, personal computers and non‐linear electronic devices in power …
automated production lines, personal computers and non‐linear electronic devices in power …
Assessing utility harmonic impedance based on the covariance characteristic of random vectors
J Hui, H Yang, S Lin, M Ye - IEEE Transactions on Power …, 2010 - ieeexplore.ieee.org
This paper presents a new method to calculate the utility harmonic impedance and the
harmonic voltage emission level at the point of common coupling (PCC). Since harmonic …
harmonic voltage emission level at the point of common coupling (PCC). Since harmonic …
A benchmark test system to evaluate methods of harmonic contribution determination
I Papič, D Matvoz, A Špelko, W Xu… - … on Power Delivery, 2018 - ieeexplore.ieee.org
Harmonic distortions at a point of common coupling (PCC) are caused by the harmonic
sources in both supply system and customer facilities. In order to verify compliance with …
sources in both supply system and customer facilities. In order to verify compliance with …
[HTML][HTML] Multi-harmonic sources identification and evaluation method based on cloud-edge-end collaboration
S Yin, Y Sun, Q Xu, K Sun, Y Li, L Ding, Y Liu - International Journal of …, 2024 - Elsevier
With the increase of power electronic devices such as distributed renewable energies,
energy storage, and flexible loads, the disturbance sources are rapidly raised and …
energy storage, and flexible loads, the disturbance sources are rapidly raised and …
Method for determining utility and consumer harmonic contributions based on complex independent component analysis
F Karimzadeh, S Esmaeili… - IET Generation …, 2016 - Wiley Online Library
This study presents a new method for determining the harmonic contributions (HCs) of utility
and consumer at the point of common coupling (PCC). The proposed method is based on a …
and consumer at the point of common coupling (PCC). The proposed method is based on a …
Harmonic contributions evaluation with the harmonic current vector method
T Pfajfar, B Blazic, I Papic - IEEE Transactions on Power …, 2007 - ieeexplore.ieee.org
A method to evaluate harmonic contributions at the point of common coupling is presented
in this paper. The proposed approach is based on the harmonic current vector method …
in this paper. The proposed approach is based on the harmonic current vector method …
Study on constraints for harmonic source determination using active power direction
F Xu, H Yang, J Zhao, Z Wang… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
The traditional active power direction (APD) method has been proven to be unreliable to
determine the dominant harmonic source at a point of common coupling (PCC), when both …
determine the dominant harmonic source at a point of common coupling (PCC), when both …
Several sufficient conditions for harmonic source identification in power systems
B Wang, G Ma, J **ong, H Zhang… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
The power direction method is a widely used method for harmonic source identification. This
method can work with no harmonic impedance information but is not theoretically rigorous …
method can work with no harmonic impedance information but is not theoretically rigorous …