Interventional CMR: clinical applications and future directions

T Rogers, RJ Lederman - Current cardiology reports, 2015 - Springer
Interventional cardiovascular magnetic resonance (iCMR) promises to enable radiation-free
catheterization procedures and to enhance contemporary image guidance for structural …

Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function

J Liu, L Feng, HW Shen, C Zhu, Y Wang… - … Resonance Materials in …, 2017 - Springer
Objective This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac
cine MRI method for cardiac function assessment. Materials and methods A golden-ratio …

Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5 T

D Jeong, ML Schiebler, P Lai, K Wang… - The international journal …, 2015 - Springer
Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free
precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left …

Optimal flip angle for high contrast balanced SSFP cardiac cine imaging

S Srinivasan, DB Ennis - Magnetic resonance in medicine, 2015 - Wiley Online Library
Purpose To determine the optimal flip angle (FA) for cardiac cine imaging that maximizes
myocardial signal and blood‐myocardium contrast. Methods Bloch equation simulations of …

[HTML][HTML] Dual echo positive contrast bSSFP for real-time visualization of passive devices duringmagnetic resonance guided cardiovascular catheterization

AE Campbell-Washburn, T Rogers, H Xue… - Journal of …, 2014 - Elsevier
Background Cardiovascular magnetic resonance (CMR) guided cardiovascular
catheterizations can potentially reduce ionizing radiation exposure and enable new …

Evaluation of a workflow to define low specific absorption rate MRI protocols for patients with active implantable medical devices

JA Martinez, K Moulin, B Yoo, Y Shi… - Journal of Magnetic …, 2020 - Wiley Online Library
Background MRI exams for patients with MR‐conditional active implantable medical devices
(AIMDs) are contraindicated unless specific conditions are met. This limits the maximum …

Fast 3D T2‐weighted imaging using variable flip angle transition into driven equilibrium (3D T2‐TIDE) balanced SSFP for prostate imaging at 3T

S Srinivasan, HH Wu, K Sung… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose Three‐dimensional (3D) T2‐weighted fast spin echo (FSE) imaging of the prostate
currently requires long acquisition times. Our objective was to develop a fast 3D T2 …

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to …

YF Peng, XY Su, LW Hu, Q Wang… - Korean Journal of …, 2021 - pmc.ncbi.nlm.nih.gov
Objective To investigate the feasibility of cine three-dimensional (3D) balanced steady-state
free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for …

Free‐breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T

S Srinivasan, RM Kroeker, S Gabriel… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose To develop a free‐breathing variable flip angle (VFA) balanced steady‐state free
precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate …

Interventional Cardiovascular Magnetic Resonance

T Rogers, R Lederman - Cardiovascular Magnetic Resonance, 2019 - Elsevier
Cardiovascular magnetic resonance (CMR) presents a number of unique opportunities to
guide transcatheter cardiovascular interventions. Advances in real-time pulse sequences …