Review on cooling system energy consumption in internet data centers
KO Amoabeng, JM Choi - International Journal of Air-Conditioning …, 2016 - World Scientific
Due to the advancement of the telecommunication and information technology (IT) industry,
internet data centers (IDCs) have become widespread in the public and private sectors. As …
internet data centers (IDCs) have become widespread in the public and private sectors. As …
Data center maintenance: applications and future research directions
Purpose One of the most critical infrastructures is a data center (DC) because of it having
many servers, computers and other equipment. DCs provide online services for various …
many servers, computers and other equipment. DCs provide online services for various …
The Energy-Saving Potential of Air-Side Economisers in Modular Data Centres: Analysis of Opportunities and Risks in Different Climates
This study examines the feasibility of utilising outside air for 'free cooling'in modular data
centres through the implementation of an air-side economiser, as an alternative to traditional …
centres through the implementation of an air-side economiser, as an alternative to traditional …
Energy Sustainability Analysis of Data Center Based on Double Cycle System with Air Free Cooling Technology
S Li, M Wang, S Qi, J Jia, Z Wang… - 2023 International …, 2023 - ieeexplore.ieee.org
Double cycle system with refrigerant-pump and vapor compression is a new refrigeration
system that uses natural cold source to dissipate heat. It is good with lower cost, more …
system that uses natural cold source to dissipate heat. It is good with lower cost, more …
Critical temperature of free cooling using indirect opening cooling tower in data centres: a review
J Liu, L Su, K Dong, X Liu - International Journal of Ambient Energy, 2022 - Taylor & Francis
The energy consumption of data centres is increasing rapidly. The key to energy saving in
the data centre is to reduce cooling energy consumption, resulting from 30–50% of the total …
the data centre is to reduce cooling energy consumption, resulting from 30–50% of the total …
Free cooling potential of an airside economizer in Estonia
Nearly zero-energy buildings are designed to minimize energy consumption and the low
energy demand is to be covered by local renewable energy resources. Free cooling is a …
energy demand is to be covered by local renewable energy resources. Free cooling is a …
[PDF][PDF] HVAC PRACTICES FOR DATA CENTERS
K YILMAZKARASU, A ONAT - ENGINEERING AND …, 2021 - researchgate.net
Today, energy consumption accounts for the majority of the import costs of develo**
countries. This necessitates examining all factors that may affect energy consumption …
countries. This necessitates examining all factors that may affect energy consumption …
[CITA][C] 济南某基站自然冷源降温系统实验研究
牛琳, 王显龙, **华山, 廉永旺, 卜宪标, 王令宝… - 新能源进展, 2017