Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Measurement of the electron magnetic moment
The electron magnetic moment,-μ/μ B= g/2= 1.001 159 652 180 59 (13)[0.13 ppt], is
determined 2.2 times more accurately than the value that stood for fourteen years. The most …
determined 2.2 times more accurately than the value that stood for fourteen years. The most …
New measurement of the electron magnetic moment and the fine structure constant
A measurement using a one-electron quantum cyclotron gives the electron magnetic
moment in Bohr magnetons, g/2= 1.001 159 652 180 73 (28)[0.28 ppt], with an uncertainty …
moment in Bohr magnetons, g/2= 1.001 159 652 180 73 (28)[0.28 ppt], with an uncertainty …
New measurement of the electron magnetic moment using a one-electron quantum cyclotron
A new measurement resolves cyclotron and spin levels for a single-electron quantum
cyclotron to obtain an electron magnetic moment, given by g/2= 1.001 159 652 180 85 …
cyclotron to obtain an electron magnetic moment, given by g/2= 1.001 159 652 180 85 …
BASE–the baryon antibaryon symmetry experiment
Abstract The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a
stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing …
stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing …
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Measurements with a one-electron quantum cyclotron determine the electron magnetic
moment, given by g/2= 1.001 159 652 180 73 (28)[0.28 ppt], and the fine structure constant …
moment, given by g/2= 1.001 159 652 180 73 (28)[0.28 ppt], and the fine structure constant …
New Determination of the Fine Structure Constant from the Electron Value and QED
Quantum electrodynamics (QED) predicts a relationship between the dimensionless
magnetic moment of the electron (g) and the fine structure constant (α). A new measurement …
magnetic moment of the electron (g) and the fine structure constant (α). A new measurement …
One-electron quantum cyclotron as a milli-eV dark-photon detector
We propose using trapped electrons as high-Q resonators for detecting meV dark photon
dark matter. When the rest energy of the dark photon matches the energy splitting of the two …
dark matter. When the rest energy of the dark photon matches the energy splitting of the two …
Phase-sensitive cyclotron frequency measurements at ultralow energies
A novel technique for a direct and coherent measurement of the modified cyclotron
frequency of an ion in a Penning trap at energies close to the thermal cooling limit is …
frequency of an ion in a Penning trap at energies close to the thermal cooling limit is …
TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz
J Ketelaer, J Krämer, D Beck, K Blaum, M Block… - Nuclear Instruments and …, 2008 - Elsevier
The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with
production rates sufficiently large for mass spectrometric and laser spectroscopic studies …
production rates sufficiently large for mass spectrometric and laser spectroscopic studies …
Levitated electromechanics: all-electrical cooling of charged nano-and micro-particles
We show how charged levitated nano-and micro-particles can be cooled by interfacing them
with an RLC circuit. All-electrical levitation and cooling is applicable to a wide range of …
with an RLC circuit. All-electrical levitation and cooling is applicable to a wide range of …