A novel resonant controller for sea-induced rotor blade vibratory loads reduction on floating offshore wind turbines
A novel multi-layer control approach for offshore floating wind turbines is presented, suitable
for alleviating the vibratory loads while kee** the generator power output stable. It consists …
for alleviating the vibratory loads while kee** the generator power output stable. It consists …
Sliding-mode control of four-leg inverter with fixed switching frequency for uninterruptible power supply applications
In three-phase transformerless uninterruptible power supply applications, a four-leg inverter
is an excellent solution to handle the full unbalanced loading condition. A sliding-mode …
is an excellent solution to handle the full unbalanced loading condition. A sliding-mode …
Deadbeat control of the stand-alone four-leg inverter considering the effect of the neutral line inductor
Distributed generation (DG) has been considered as an alternative source of power
generation, especially in stand-alone applications, where both single-and three-phase loads …
generation, especially in stand-alone applications, where both single-and three-phase loads …
Five-level E-type inverter for grid-connected applications
M di Benedetto, A Lidozzi, L Solero… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
Nowadays, a multilevel converter represents a good idea for commercial and industrial
applications, where small size and cost, low maintenance, reliability in a wide range of …
applications, where small size and cost, low maintenance, reliability in a wide range of …
A hybrid FCS-MPC with low and fixed switching frequency without steady-state error applied to a grid-connected CHB inverter
This paper presents a new finite control set model predictive control strategy that, contrary to
conventional approaches, achieves (i) zero steady-state error in the converter's AC current …
conventional approaches, achieves (i) zero steady-state error in the converter's AC current …
Design and implementation of reduced grid impact charging station for public transportation applications
This paper deals with the complete design procedure, implementation and control software
realization for a multi-converter charging station with reduced grid impact due to local …
realization for a multi-converter charging station with reduced grid impact due to local …
Digital single voltage loop control of a VSI with LC output filter
This paper deals with the output voltage control problem of a three-phase three-wire voltage
source Inverter (VSI) with LC output filter. A novel discrete-time active dam** technique is …
source Inverter (VSI) with LC output filter. A novel discrete-time active dam** technique is …
Fully discrete-time domain model and dam** characteristics accurate analysis for grid-connected inverter with LCL filter
W Wu, K Hu, M Zhang, G Han - Electric Power Systems Research, 2023 - Elsevier
Grid-connected inverter with LCL filter, which is regarded as a common interface, plays a
significant role in distributed generation system. In order to promise the steady-state and …
significant role in distributed generation system. In order to promise the steady-state and …
Comparison of three voltage saturation algorithms in shunt active power filters with selective harmonic control
An array of proportional-resonant regulators is often used in shunt active power filters to
control the grid currents and reduce the harmonic distortion caused by a distorting load. The …
control the grid currents and reduce the harmonic distortion caused by a distorting load. The …
Constant delay-line frequency adaptive repetitive-resonant control for grid-tied and intentional islanding operations
M di Benedetto, A Faro, L Bigarelli… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
Repetitive Control (RC) enables inverters to inject, at fundamental frequency, high quality
sinusoidal current into the grid or to provide low THD voltages in off-grid applications …
sinusoidal current into the grid or to provide low THD voltages in off-grid applications …