Grid integration challenges of wind energy: A review

SD Ahmed, FSM Al-Ismail, M Shafiullah… - Ieee …, 2020 - ieeexplore.ieee.org
The strengthening of electric energy security and the reduction of greenhouse gas
emissions have gained enormous momentum in previous decades. The integration of large …

A comprehensive overview of power converter applied in high-power wind turbine: Key challenges and potential solutions

P Catalán, Y Wang, J Arza… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The increasing penetration of offshore wind power generation promotes the revolution of
wind turbine toward high-power application. The development of high-power wind turbine …

Comprehensive overview of low voltage ride through methods of grid integrated wind generator

OP Mahela, N Gupta, M Khosravy, N Patel - Ieee Access, 2019 - ieeexplore.ieee.org
The wind power generation is a rapidly growing grid integrated renewable energy (RE)
technology with an installed capacity of 539.291 GW. The capability of the wind energy …

[HTML][HTML] Energy reliability enhancement of a data center/wind hybrid DC network using superconducting magnetic energy storage

X Chen, M Zhang, S Jiang, H Gou, P Zhou, R Yang… - Energy, 2023 - Elsevier
The progressive penetrations of sensitive renewables and DC loads have presented a
formidable challenge to the DC energy reliability. This paper proposes a new solution using …

Hybrid LVRT control of doubly-fed variable speed pumped storage to shorten crowbar operational duration

D Zhu, Z Wang, Y Ma, J Hu, X Zou… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Crowbar is the most widely used low voltage ride-through (LVRT) solution for doubly-fed
variable speed pumped storage (VSPS) unit. However, the conventional crowbar solution …

An Improved Design of Current Controller for LCL-Type Grid-Connected Converter to Reduce Negative Effect of PLL in Weak Grid

S Zhou, X Zou, D Zhu, L Tong, Y Zhao… - IEEE Journal of …, 2017 - ieeexplore.ieee.org
For three-phase LCL-type grid-connected converter, when it is attached to weak grid, current
control interacts with phase-locked loop (PLL) via point of common coupling voltage …

Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid

D Zhu, S Zhou, X Zou, Y Kang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …

Unified power quality conditioner with advanced dual control for performance improvement of DFIG-based wind farm

RH Yang, JX ** - IEEE Transactions on Sustainable Energy, 2020 - ieeexplore.ieee.org
The weakness of low voltage ride-through capacity, power oscillations under asymmetrical
fault and the instability of the output power are three major difficulties that need to be …

Comprehensive review on low voltage ride through capability of wind turbine generators

R Hiremath, T Moger - International Transactions on Electrical …, 2020 - Wiley Online Library
Wind energy has made more inroads in renewable power generation due to environmental
impact of conventional energy sources. The high penetration of grid connected wind energy …

Combined low voltage ride through and power smoothing control for DFIG/PMSG hybrid wind energy conversion system employing a SMES-based AC-DC unified …

JX **, RH Yang, RT Zhang, YJ Fan, Q **e… - International Journal of …, 2021 - Elsevier
Abstract An Interline AC-DC unified power quality conditioner (UPQC) protection device is
proposed and designed based on superconducting magnetic energy storage (SMES) in this …