Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Prompt-gamma monitoring in hadrontherapy: A review
Secondary radiation emission induced by nuclear reactions is correlated to the path of ions
in matter. Therefore, such penetrating radiation can be used for in vivo control of …
in matter. Therefore, such penetrating radiation can be used for in vivo control of …
Range verification methods in particle therapy: underlying physics and Monte Carlo modeling
AC Kraan - Frontiers in oncology, 2015 - frontiersin.org
Hadron therapy allows for highly conformal dose distributions and better sparing of organs-
at-risk, thanks to the characteristic dose deposition as function of depth. However, the quality …
at-risk, thanks to the characteristic dose deposition as function of depth. However, the quality …
A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy
F Hueso-González, M Rabe, TA Ruggieri… - Physics in Medicine …, 2018 - iopscience.iop.org
We present a full-scale clinical prototype system for in vivo range verification of proton pencil-
beams using the prompt gamma-ray spectroscopy method. The detection system consists of …
beams using the prompt gamma-ray spectroscopy method. The detection system consists of …
Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification
JC Polf, S Avery, DS Mackin… - Physics in Medicine & …, 2015 - iopscience.iop.org
The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to
measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for …
measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for …
First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility
F Hueso-González, W Enghardt, F Fiedler… - Physics in Medicine …, 2015 - iopscience.iop.org
Ion beam therapy promises enhanced tumour coverage compared to conventional
radiotherapy, but particle range uncertainties significantly blunt the achievable precision …
radiotherapy, but particle range uncertainties significantly blunt the achievable precision …
Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery
T Werner, J Berthold, F Hueso-González… - Physics in Medicine …, 2019 - iopscience.iop.org
In proton therapy, patients benefit from the precise deposition of the dose in the tumor
volume due to the interaction of charged particles with matter. Currently, the determination of …
volume due to the interaction of charged particles with matter. Currently, the determination of …
Proton therapy monitoring: spatiotemporal emission reconstruction with prompt gamma timing and implementation with PET detectors
Objective. In this study we introduce spatiotemporal emission reconstruction prompt gamma
timing (SER-PGT), a new method to directly reconstruct the prompt photon emission in the …
timing (SER-PGT), a new method to directly reconstruct the prompt photon emission in the …
Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy
F Hueso-González, F Fiedler, C Golnik… - Frontiers in …, 2016 - frontiersin.org
Proton beams are promising means for treating tumors. Such charged particles stop at a
defined depth, where the ionization density is maximum. As the dose deposit beyond this …
defined depth, where the ionization density is maximum. As the dose deposit beyond this …
Spectroscopic study of prompt-gamma emission for range verification in proton therapy
L Kelleter, A Wrońska, J Besuglow, A Konefał… - Physica Medica, 2017 - Elsevier
We present the results of an investigation of the prompt-gamma emission from an interaction
of a proton beam with phantom materials. Measurements were conducted with a novel setup …
of a proton beam with phantom materials. Measurements were conducted with a novel setup …
Short-lived positron emitters in beam-on PET imaging during proton therapy
P Dendooven, HJT Buitenhuis, F Diblen… - Physics in Medicine …, 2015 - iopscience.iop.org
The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical
use today is positron emission tomography (PET) of the positron emitters produced in the …
use today is positron emission tomography (PET) of the positron emitters produced in the …