Virtual clinical trials in medical imaging: a review
The accelerating complexity and variety of medical imaging devices and methods have
outpaced the ability to evaluate and optimize their design and clinical use. This is a …
outpaced the ability to evaluate and optimize their design and clinical use. This is a …
XOP v2. 4: Recent developments of the X-ray optics software toolkit
MS del Río, RJ Dejus - … in Computational Methods for X-Ray …, 2011 - spiedigitallibrary.org
XOP v2. 4 consists of a collection of computer programs for calculation of radiation
characteristics of X-ray sources and their interaction with matter. Many of the programs …
characteristics of X-ray sources and their interaction with matter. Many of the programs …
Dedicated breast CT: radiation dose and image quality evaluation
JM Boone, TR Nelson, KK Lindfors, JA Seibert - Radiology, 2001 - pubs.rsna.org
PURPOSE: To evaluate the feasibility of breast computed tomography (CT) in terms of
radiation dose and image quality. MATERIALS AND METHODS: Validated Monte Carlo …
radiation dose and image quality. MATERIALS AND METHODS: Validated Monte Carlo …
Tungsten anode spectral model using interpolating cubic splines: unfiltered x‐ray spectra from 20 kV to 640 kV
Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x‐ray
spectra spanning from 20 kV to 640 kV. Methods: X‐ray spectra were simulated for a …
spectra spanning from 20 kV to 640 kV. Methods: X‐ray spectra were simulated for a …
Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols
Abstract The United Kingdom, European and IAEA protocols for breast dosimetry in
mammography make use of s-factors which allow for the use of different target/filter …
mammography make use of s-factors which allow for the use of different target/filter …
Spektr: a computational tool for x‐ray spectral analysis and imaging system optimization
A set of computational tools are presented that allow convenient calculation of x‐ray spectra,
selection of elemental and compound filters, and calculation of beam quality characteristics …
selection of elemental and compound filters, and calculation of beam quality characteristics …
Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment
JM Boone - Radiology, 1999 - pubs.rsna.org
PURPOSE: To extend the utility of normalized glandular dose (D gN) calculations to higher x-
ray energies (up to 120 keV) and to provide the tools for investigators to calculate D gN …
ray energies (up to 120 keV) and to provide the tools for investigators to calculate D gN …
Clinical digital breast tomosynthesis system: dosimetric characterization
SSJ Feng, I Sechopoulos - Radiology, 2012 - pubs.rsna.org
Purpose To comprehensively characterize the dosimetric properties of a clinical digital
breast tomosynthesis (DBT) system for the acquisition of mammographic and tomosynthesis …
breast tomosynthesis (DBT) system for the acquisition of mammographic and tomosynthesis …
Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols
A formalism is proposed for the estimation of mean glandular dose for breast tomosynthesis,
which is a simple extension of the UK, European and IAEA protocols for dosimetry in …
which is a simple extension of the UK, European and IAEA protocols for dosimetry in …
Flat-field correction technique for digital detectors
JA Seibert, JM Boone… - Medical Imaging 1998 …, 1998 - spiedigitallibrary.org
The effects of the stationary noise patterns and variable pixel responses that commonly
occur with uniform exposure of digital detectors can be effectively reduced by simple'flat …
occur with uniform exposure of digital detectors can be effectively reduced by simple'flat …